BDS 275 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 116

Read Harman Kardon BDS 275 EMC - CB Certificate online

Page 56 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
SE  Sweden 
 
(after the compliance statement) 
already part of A11 (This note will be deleted from 
the final text) 
 
 
 
US  United States of America 
US 
1.1.1 
Scope clarification: 
The standard also covers commercial and 
professional apparatus; professional apparatus 
may also be investigated using UL 1419. 
Projection apparatus is not covered. Household 
games, household gaming and scoring machines, 
satellite receiver antenna positioners are covered 
by this standard but commercial games and 
commercial gaming and scoring machines, and 
other types of antenna positioners are covered by 
other standard. 
Add: Mains connected apparatus intended for 
field installation requires compliance with the 
National Electrical Code, ANSI, NFPA 70. 
 
1.1.3 
Protection against splashing water replaced with 
apparatus intended for outdoor use (See Annex 
A). 
 
N/A 
1.1.5 
Add: Some equipment covered by these 
requirements may also be required to comply with 
applicable requirements in other standards 
 
N/A 
1.2 
Add references to ANSI, ASTM and UL standards   
4.2.1 
Add Note: In the U.S. the RATED SUPPLY 
VOLTAGE for single-phase apparatus is 
assumed to be 120 V or 120/240 V. 
 
4.2.4 
Revision to sub-clause a): Minimum audio output 
is not less than 0.5 W per channel unless the 
maximum audio output is less than 0.5 W per 
channel. 
 
N/A 
4.2.4.1 
Add: ―An apparatus with multiple modes of 
operation, multiple signal input sources, or both, 
is to be operated using each mode of operation or 
signal input source separately, or in combination, 
according to the manufacturer‘s instructions to 
produce the maximum power input‖. 
Table 2: External supply sources are assumed to 
be capable of delivering 30 A, unless otherwise 
specified (no-load voltage and internal resistance 
values in the Table are modified). 
 
4.3.4 
Add: PTC thermistors may also comply with UL 
1434. 
 
N/A 
Page of 127