Read Sony DCR-DVD406E / DCR-DVD408 / DCR-DVD408E / DCR-DVD506E / DCR-DVD508 / DCR-DVD508E / DCR-DVD808 / DCR-DVD808E / DCR-DVD908 / DCR-DVD908E (serv.man6) Service Manual online
• Change of Note 3 for Alignment Disc
• Addition of “Shift Lens Check”
• Addition of Note for Record Data
been changed from Ver_1.0r01 into Ver_1.2r02.
Ver_1.2r02.exe), and the Automatic Adjustment Program will start.
screen in Fig. 6-1-9 will appear. On this screen, select each adjust-
ment section.
gram.
The disc use counts are saved in the PC. Accordingly, the disc and PC used for diagnosis and adjustment must always be
controlled in the same combination.
If the disc is used with another PC, it will be recognized as a new disc, causing the use limit to be unknown.
message window.
The disc use counts are saved in the PC. Accordingly, the disc used for diagnosis and adjustment, PC and drive adjustment
program (AUDIT for 2007) must always be controlled in the same combination.
If the disc is used with another PC or other versions (AUDIT for Service, AUDIT for UX1, etc.), the diagnosis and adjust-
ment will fail and that disc will no longer be able to use.
Click the [SERVICE MODE] button on the Main Menu screen, and
the “SERVICE MODE” screen in Fig. 6-3-2 will appear.
The Main Menu screen comes back.
“SWITCH CHECK” screen appears.
“LED CHECK” screen appears.
“JACK CHECK” screen appears.
“LENS BARRIER CHECK” screen appears.
“RECORD DATA” screen appears.
“SHIFT LENS CHECK” screen appears.
Click the [Record Data] button on the SERVICE MODE screen,
and the “RECORD DATA” screen will appear.
displayed.
Click the [Clear Self-Diagnosis Data Only] button on the screen, and
the Self-Diagnosis Data will be initialized.
error cannot be reset by initializing the self-diagnosis data
only.
Click the [Clear All Recorded-Data] button on the screen, and the
All Recorded-Data will be initialized.
Note: Performing the initialization causes all the user settings in-
Use this menu when E:62:11 (Shift Lens Overheating (Pitch))
occurred.
Click the [Check 2 Start] button, and the shift lens will move in
up and down directions. If the shift lens does not move, replace
the lens block.
Use this menu when E:62:12 (Shift Lens Overheating (Yaw))
occurred.
Click the [Check 3 Start] button, and the shift lens will move in
left and right directions. If the shift lens does not move, replace
the lens block.
codes are displayed.
and the “SHIFT LENS CHECK” screen will appear.
Use this menu when E:62:10 (Shift Lens Initializing Failure) oc-
curred.
Click the [Check 1 Start] button, and the “EEPROM Check” and
“Steady Hall Adjustment” will be executed.
move in up, down, left, and right directions. If the shift lens
does not move at all and a message “Shift Lens Check 1 Com-
plete” is displayed, or if an error message of Steady Hall Ad-
justment is displayed, replace the lens block.
of the IC1803 on the VC-478 board, when the following mes-
sage is displayed.