DCR-DVD406E/DVD408/DVD408E/DVD506E/DVD508/DVD508E/DVD808/DVD808E/DVD908/DVD908E_ADJ
• Addition of “Shift Lens Check”
&
: Points added portion.
6-3. SERVICE MODE
3-2.
SERVICE MODE
1.
Function of Each Button on Service Mode Screen
(Service manual page 6-53)
Click the [SERVICE MODE] button on the Main Menu screen, and
the “SERVICE MODE” screen in Fig. 6-3-2 will appear.
Click the [SERVICE MODE] button on the Main Menu screen, and
the “SERVICE MODE” screen in Fig. 6-3-2 will appear.
Fig. 6-3-2
1
[To Menu] button
The Main Menu screen comes back.
The Main Menu screen comes back.
2
[Switch Check] button
“SWITCH CHECK” screen appears.
“SWITCH CHECK” screen appears.
3
[LED Check] button
“LED CHECK” screen appears.
“LED CHECK” screen appears.
4
[Jack Check] button
“JACK CHECK” screen appears.
“JACK CHECK” screen appears.
5
[Lens Barrier Check] button
“LENS BARRIER CHECK” screen appears.
“LENS BARRIER CHECK” screen appears.
6
[Record Data] button
“RECORD DATA” screen appears.
“RECORD DATA” screen appears.
7
[Shift Lens Check] button
“SHIFT LENS CHECK” screen appears.
“SHIFT LENS CHECK” screen appears.
*
• Addition of Note for Record Data
&
: Points added portion.
6.
Record Data
(Service manual page 6-55)
Click the [Record Data] button on the SERVICE MODE screen,
and the “RECORD DATA” screen will appear.
Click the [Record Data] button on the SERVICE MODE screen,
and the “RECORD DATA” screen will appear.
The record data such as use record and self-diagnostic record are
displayed.
displayed.
Initializing method (Self-Diagnosis Data Only):
Click the [Clear Self-Diagnosis Data Only] button on the screen, and
the Self-Diagnosis Data will be initialized.
Click the [Clear Self-Diagnosis Data Only] button on the screen, and
the Self-Diagnosis Data will be initialized.
Note: If a flash error (self-diagnosis code E:91:**) occurred, all
recorded data must be initialized to reset the error. The
error cannot be reset by initializing the self-diagnosis data
only.
error cannot be reset by initializing the self-diagnosis data
only.
Initializing method (All Record-Data):
Click the [Clear All Recorded-Data] button on the screen, and the
All Recorded-Data will be initialized.
Note: Performing the initialization causes all the user settings in-
Click the [Clear All Recorded-Data] button on the screen, and the
All Recorded-Data will be initialized.
Note: Performing the initialization causes all the user settings in-
cluding time setting to be initialized, too.
(
1
5
2
3
4
6
7