Read Sharp MX-PE10 FIERY (serv.man45) Technical Bulletin online
Page 5 of 8
Disclaimer
This hardware, software/patches, or technology may contain cryptographic functions as defined in Article 8 (ix) (h) because the cryptographic capability is
not user-accessible, and are designed to have only one or more of the following cryptographic functionality(ies):
1 Functionality to execute copy-protected programs
2 Functionality to access to digital contents stored on copy-protected read-only media
3 Functionality to access to encrypted and memorized digital contents on a medium that will be sold to the public with the same content
4 Functionality for copying control of copyright protected audio/video data
5 Functionality to encrypt and/or decrypt to protect libraries, design attributes, or associated data for the design of semiconductor devices or integrated
circuits
©2012 Electronics For Imaging
Customer Support
Release Note
• FIT191575: When reaching account limitation, bring it to toner not mounted
status, although MFP status is account limit, Command WorkStation status is
toner not mounted.
toner not mounted.
1. In Command WorkStation register a user
from menu create in [Server]-[Configure]、[User and Group]
Ex. Group: test, User:test1, Password:00000
2. Register user in printer driver
From OS"Device and Printer" right click on printer and select [Printing
Preferences]
In [Job Info], set[User authentication]
Ex.User:test1、Password:00000
3.In MFP Web page, register a user
Create in [User Control]-[User List]
Ex.User:test1、Password:00000
4. Set a limitation on user created in MFP Web page
From [User Control]-[Page Limit Group List], Create print count limitation 1group
Set this created limitation group to prerequestie-3 user
【Procedure】
1. Print out 2 sets of test page from printer driver
2. When having account limitation, take out toner cartridge from MFP
3. Check MFP operation screen
4. Check MFP Web page
5. Check Command WorkStation status
Results
Procedure 2: It has the display of account limit and toner not mounted
Procedure 3: Account limit is displayed
Procedure 4: Toner not mounted is displayed
• FIT191581: Print job is canceled when print job is sent. Fiery does not receive
the packet that an engine sent.
1) Set 20 sheets of paper in LCC, Tray1, Tray2 and bypass tray.
2) Shift to Auto Power Shut-Off of MFP.
3) Print core_10_b.pdf(1082page)with letter LEF from Fiery driver.
4) Paper is not enough in the middle of a job.
And set paper in order of Tray5, Tray1, Tray2, bypass tray.
Results: Print job is canceled