  IC card reader  6 – 4
Display when loading is failed:
When an error occurs, troubleshoot the cause and remove the trou-
ble. Then perform the above procedures again. 
Possible causes for an error may be error of the IC card or
improper contents of the setting file for HID card reading.
3.  Setting file for HID card reading
A. Overview
This manual describes the following setting procedures for reading
data from an IC card by using the HID card reading function:
? Setting of the reading area of card data
? Setting for assignment of read data to the card ID and the facility
code
* If the above setting procedures are not completed, the default
setting is valid, reading all the data in the card and assigning to
the card ID.
The brief steps of the setting are:
? Make the setting file according to the format specified in this
manual.
? Import the setting file through web page or by using the system
setting of the machine, "HID user area setting"
Incase of System setting mode:
User control > Card area setting > Importing from the setup file
B. Format of the setting file
The format of the setting file should be as shown below:
Section name
Key name = Key value
* Use the template setting file, change the key value, make an
arbitrary file name with an arbitrary extension (such as .ini), and
save the file.
? A line started with "#" or ";" is treated as a comment.
? A blank line may be inserted.
? Use one-byte alphanumeric characters only (except for comment
lines).
? A one-byte space may be inserted in front of and at the back of
"=" which connects the key name and the key value.
? Characters for the key value are case-insensitive. ("ABCD" is
considered as the same as "abcd".)
The section name (which is not changed in principle) and the key
name must be distinguished each other. 
? The size of the setting file must be 4KByte or less.
? For the keys which are not set, the column of the value must be
blank or the whole line may be deleted (commented out). 
C. Descriptions on the setting file
(1)
Setting of the general information
*1: This manual describes only the setting of the HID card.
(2)
Setting of the HID setting file
For [Decoding\CardId] section, the same as above.
When Data = #!abcde$12345%vxxyz ;
Example 1: Specification by position
Position = 3
Length = 5
 -> Decoded Data = abcde
Example 2: Specification by delimiter
Start.Delimiter = $
End.Delimiter = %
 -> Decoded Data = 12345
Detail of error
Error display
Error content and remedy
Card is not 
found.
Content
The card is not detected.
Remedy
Check to confirm that the card is securely 
inserted into the IC card reader.
Read Error.
Content
A read error occurs.
Remedy
Check to confirm that the card and the card 
reader operate normally with a personal 
computer, etc.
Section name
Description
General
Setting of the general information
Read Success.
Card ID : XXXXX
Facility Code : XXXXX
[General]
Key name
Description
Version
Setting file version (* Fixed to 1.0)
Card
Set as shown below depending on the kind of the card to be 
set. 
*1
Key value
Description
Felica FeliCa
Card
Hid HID
Card
Section name
Description
Decoding\Facility
Code
Decode setting of the facility code. 
(* If the facility code is not used, there is no need to 
describe this item.)
Decoding\CardId
Decode setting of the card ID. 
(* If the card ID is not decoded and all the read data 
are used for the card ID, there is no need to describe 
this item.)
[ Decoding\FacilityCode]
Key name
Description
Location
Location specifying method
ByPosition: Specifying by position
ByDelimiter: Specifying by delimiter
* If the facility code has no setting of this item, it is NULL.
* If the card ID has no setting of this item, all the data read 
from the card is made the card ID.
Position
Start position (1 - 128) is specified with a decimal number. 
(* Specified only when the location key value is 
"ByPosition".)
* The head is specified with 1 and later.
Length Position
The length of reading from the position specified with the 
key is specified with a decimal number (1 - 128). 
(* Specified only when the location key value is 
"ByPosition".)
* The total of this set value and the value specified with 
Position key must be 128+1 or less.
Start.Delimiter
Delimiter (Front) 
(* Specified only when the location key value is 
"ByDelimiter".)
* Only ASCII code printable characters can be used for 
specification.
End.Delimiter
Delimiter (Back)
(* Specified only when the location key value is 
"ByDelimiter".)
* Only ASCII code printable characters can be used for 
specification.
Section name
Description
Padding\CardId
Card ID padding setting
[Padding\Data]
Key name
Description
Pre
Front padding (Max. 3 characters)
* Only ASCII code printable characters can be used 
for specification.