MX-6201N, MX-7001N (serv.man19). SIMULATIONS SECTION - Sharp Copying Equipment Service Manual (repair manual). Page 127

Read Sharp MX-6201N / MX-7001N (serv.man19) Service Manual online

MX-7001N  SIMULATION  7 – 127
53
5
Dial tone monitoring time
1: 17 seconds
0: 10 seconds
"1": 17 seconds 
(Germany/
Switcherland/Austria)
"0": 10 seconds 
(Other country)
6
CNG detection when calling 
FAX
1: CNG detection ON
0: CNG detection OFF
0
OFF
For collision 
aversion
7, 8
DT/BT detection level
-43dB
0 0
0
-43dB
DT, BT common
-35dB
0 1
0
-33dB
1 0
-30dB
1 1
54
1, 2
DT/BT detection frequency 
range setting
Modem fixed 
(About 308Hz to 517Hz)
0 0
"00": Modem fixed 
(Thailand/India)
"01": 420Hz to 680Hz 
(China)
"10": 360Hz to 440Hz 
(Indonesia/Malaysia/
Middle East/Other3/
Rusia)
"11": 245Hz to 650Hz 
(Other country)
For CTR21: 245Hz 
to 650Hz
420Hz to 680Hz
0 1
360Hz to 440Hz
1 0
245Hz to 650Hz
1 1
3
Busy tone detection
1: No
0: Yes
0
Yes
4, 5
Busy tone detection interval
2 pulse
0 0
"00": 2 pulse (North 
America/Australia/
New Zealand/China/
Singapore/Indonesia/
Thailand/Malaysia/
India/Philippine/
Hong Kong/Taiwan/
Middle East/Other3)
"01": 3 pulse 
(Other country)
3 pulse
0 1
4 pulse
1 0
6 pulse
1 1
6, 7
DP dial pulse count 
handling
NORMAL 
(Pulse=DIAL, 10=0)
0 0
"01": EXTEND 
(Sweden)
"10": REVERSE 
(New Zealand)
"00": NORMAL 
(Other country)
EXTEND 
(Pulse=DIAL+1)
0 1
REVERSE 
(Pulse=10-DIAL)
1 0
8
Not used
0
55
1 - 8
Not used
0
56
1 - 4
Adjustment 
value
Make time (10PPS) setting
Setting range
Binary input
29 to 44ms
1ms intervals
"0100": 33ms 
(Malaysia/Taiwan/
South Africa)
"0110": 35ms 
(New Zealand/India)
"1000": 37ms 
(Australia)
"1001": 38ms 
(China/Singapore/
Thailand/Hong Kong)
"1011": 40ms 
(Other country)
5 - 8
Adjustment 
value
Break time setting (10PPS)
Setting range
Binary input
56 to 71ms
1ms intervals
"0110": 62ms 
(China/Singapore/
Thailand/Hong Kong)
"0111": 63ms 
(Australia)
"1001": 65ms 
(New Zealand/India)
"1011": 67ms 
(Malaysia/Taiwan/
South Africa)
"0100": 60ms 
(Other country)
57
1 - 4
Adjustment 
value
Minimum pause time 
(10PPS) setting
Setting range
Binary input
800ms to 950ms
10ms intervals
"0001": 810ms 
(France)
"0000": 800ms 
(Other country)
5 - 8
Adjustment 
value
Minimum pause time 
(20PPS) setting
Setting range
Binary input
450ms to 600ms
10ms intervals
0
450ms
Functions only in 
China and 
Thailand.
0
0
0
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
Page of 127
Display