MX-6201N, MX-7001N (serv.man19). SIMULATIONS SECTION - Sharp Copying Equipment Service Manual (repair manual). Page 121

Read Sharp MX-6201N / MX-7001N (serv.man19) Service Manual online

MX-7001N  SIMULATION  7 – 121
23
7
Polling 
protection 
setting
Polling protection
1: Do not protect
0: Protect
0
Protect
8
Switch to sorting in order of 
numbers on the address list
1: Registered number 
order
0: Search number order
0
Search number 
order
24
1
Receiver off-hook (External 
telephone)
1: Warns off-hook state 
of the external 
telephone.
0: Does not warn off-
hook state of the 
external telephone.
"0": Does not warn off-
hook state of the 
external telephone. 
(North America/
Australia/New 
Zealand/China/
Singapore/Indonesia/
Thailand/Malaysia/
India/Philippine/Hong 
Kong/Taiwan/Middle 
East/Other3)
"1": Warns off-hook 
state of the external 
telephone. 
(Other country)
Limited by the TEL/
LIU PWB.
2 - 5
Not used
1
0
0
0
6
Scope of line sound monitor
1: All
0: Until NSF signal send/
receive
0
Until NSF signal 
send/receive
7, 8
(*)
Volume setting of call sound 
(large)
Volume level 9
0 0
1
Volume level 13
Related to BZ
Calling sound/ 
Communication end 
sound (Normal, 
Error)
Volume level 11
0 1
0
Volume level 13
1 0
Volume level 15
1 1
25
1, 2
(*)
Volume setting of call sound 
(medium)
Volume level 3
0 0
0
Volume level 5
Related to BZ
Calling sound/ 
Communication end 
sound (Normal, 
Error)
Volume level 5
0 1
1
Volume level 7
1 0
Volume level 9
1 1
3, 4
(*)
Volume setting of call sound 
(small)
Volume level 0 
(no sound)
0 0
1
Volume level 2
Related to BZ
Calling sound/ 
Communication end 
sound (Normal, 
Error)
Volume level 1
0 1
0
Volume level 2
1 0
Volume level 3
1 1
5, 6
(*)
Volume setting of line 
monitor sound (large)
Volume level 9
0 0
1
Volume level 15
Line Monitor sound
When on-hook
Receiver off-hook 
warning sound
Volume level 11
0 1
1
Volume level 13
1 0
Volume level 15
1 1
7, 8
(*)
Volume setting of line 
monitor sound (medium)
Volume level 5
0 0
1
Volume level11
Line Monitor sound
When on-hook
Receiver off-hook 
warning sound
Volume level 7
0 1
1
Volume level 9
1 0
Volume level11
1 1
26
1, 2
(*)
Volume setting of line 
monitor sound (small)
Volume level 1
0 0
1
Volume level 5
Line Monitor sound
When on-hook
Receiver off-hook 
warning sound
Volume level 3
0 1
0
Volume level 5
1 0
Volume level 7
1 1
3
Not used
0
4
Remote changeover 
permitted
1: Changeover enable 
for call-out/call-in
0: Changeover enable 
only for call-in
0
Only for call-in
North America: This 
SW is ignored and 
changeover is 
enabled for call-out/
call-in.
5 - 7
Setting of call time (T0 timer 
setting) in automatic 
transmission
Setting range <Binary input>
(Rusia) 30 seconds to 35 seconds: 
5 seconds intervals
(China) 30 seconds to 45 seconds
(Other country) 30 seconds to 60 seconds: 
15 seconds intervals
"001": 35 seconds 
(Rusia)
"001": 45 seconds 
(Other country)
For outside the set 
range, the default 
value is used.
8
External telephone setting 
when no sound is set
1: No sound priority
0: Priority on external 
telephone send
0
Priority on 
external telephone 
send
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
Page of 127
Display