MX-7001N  SIMULATION  7 – 124
39
1
Echo countermeasure (CED 
tone sending interval) when 
receiving
1: 500ms
0: 75ms
0
75ms
2
Echo countermeasure 
(setting of hold time 
between DIS reception and 
sending of signal) when 
transmitting
1: 800ms
0: 500ms
0
500ms
Enable for other 
than V.34
3 - 6
Not used
0
0
0
1
7, 8
RTN sending line error rate
6line
0 0
1
60line
Number of error 
lines in the STD 
standard
12line
0 1
0
60line
1 0
120line
1 1
40
1
CSI sending
1: No
0: Yes
0
Yes
2, 3
CED signal sending time
3 seconds
0 0
0
3 seconds
Setting for the 
ANSam signal is 
performed using a 
separate SW 51-7, 
8 (V.8 mode 
ANSam signal 
sending time).
4 seconds
0 1
0
5 seconds
1 0
No
1 1
4
CED/ANSam detection time
1: 1000ms
0: 500ms
0
500ms
5, 6
Waiting time for start of 
CED/ANSam sending
2.25 seconds
0 0
0
2.25 seconds
3 seconds
0 1
0
4 seconds
1 0
7, 8
Not used
0
0
41
1, 2
Start of CNG sending
0.5 seconds
0 0
"11": 2.0 seconds 
(North America/
Taiwan/Middle East/
Other3/Rusia)
"00": 0.5 seconds 
(Other country)
1.0 second
0 1
1.5 seconds
1 0
2.0 seconds
1 1
3
Time between DCS-TCF
1: 150ms
0: 75ms
0
75ms
4 - 8
Not used
0
1
0
0
0
42
1, 2
RCP sending count
3 times
0 0
0
3 times
6 times
0 1
0
9 times
1 0
12 times
1 1
3
RTC EOL sending count
1: 12 times
0: 6 times
0
6 times
4
F.A.S.T function
1: Yes
0: No
0
No
Valid only in North 
America.
5 - 8
Not used
0
1
1
1
43
1
V.34 mode function 
(including polling when 
calling)
1: V.34 invalid
0: V.34 valid
0
V.34 valid
2
V.34 mode function (on call 
arrival)
1: V.34 invalid
0: V.34 valid
0
V.34 valid
3
V.34 mode function at times 
of manual communication
1: V.34 invalid
0: V.34 valid
0
V.34 valid
4
Primary channel return 
mode setting
1: PPh
0: Sh
1
PPh
5, 6
External telephone off-hook 
detection time when 
simulated voltage is applied
48ms
0 0
0
96ms
96ms
0 1
1
200ms
1 0
300ms
1 1
7
Reversion from the energy 
saving state (excluding 
preheat) when the external 
telephone is off-hook
1: Revert
0: Do not revert
1
Revert
8
Not used
0
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
Page of 127