Read Sharp MX-1800N (serv.man16) Service Manual online
MX-1800N SELF DIAG AND TROUBLE CODE 8 – 24
U2-90
EEPROM read/write error
(PCU detection)
(PCU detection)
U2-91
EEPROM (PCU) check sum error
U6-00
Desk communication trouble
U6-01
Tray 1 lift-up trouble
U6-02
Tray 2 lift-up trouble
U6-10
Desk transport motor trouble
U6-50
Desk incompatibility trouble
UC-02
CPT-ASIC abnormality
UC-20
Document control module trouble
Trouble content
EEPROM version error, write error to EEPROM
Section
PCU
Case 1
Cause
EEPROM trouble, installation of EEPROM which
is not initialized
is not initialized
Check and
remedy
remedy
Check that EEPROM is properly set.
Case 2
Cause
PCU PWB EEPROM access circuit trouble
Check and
remedy
remedy
To avoid deletion of the counter data/adjustment
data, use the simulation to save the counter/
adjustment values. (If there is a printer option,
execute SIM22-1 to save the counter data and the
adjustment values.) Replace the PCU PWB. Use
SIM16 to cancel the trouble.
data, use the simulation to save the counter/
adjustment values. (If there is a printer option,
execute SIM22-1 to save the counter data and the
adjustment values.) Replace the PCU PWB. Use
SIM16 to cancel the trouble.
Trouble content
Check sum error of adjustment value (PCU)
Section
PCU
Case 1
Cause
Control circuit hang-up due to electrical noises
Check and
remedy
remedy
Use SIM16 to cancel the trouble.
Case 2
Cause
EEPROM trouble.
Check and
remedy
remedy
Check that EEPROM is properly set.
Case 3
Cause
PCU PWB EEPROM access circuit trouble
Check and
remedy
remedy
To avoid deletion of the counter data/adjustment
data, use the simulation to save the counter/
adjustment values. (If there is a printer option,
execute SIM22-1 to save the counter data and the
adjustment values.) Replace the PCU PWB.
data, use the simulation to save the counter/
adjustment values. (If there is a printer option,
execute SIM22-1 to save the counter data and the
adjustment values.) Replace the PCU PWB.
Trouble content
Desk communication error, communication line
test error after turning on the power or canceling
the exclusive simulation
test error after turning on the power or canceling
the exclusive simulation
Section
PCU
Case 1
Cause
Connector and harness connection trouble or
disconnection, desk control PWB trouble, control
PWB (PCU) trouble, malfunction due to electrical
noises
disconnection, desk control PWB trouble, control
PWB (PCU) trouble, malfunction due to electrical
noises
Check and
remedy
remedy
Cancel the trouble by turning OFF/ON. Check the
connector and the harness of the communication
line.
connector and the harness of the communication
line.
Trouble content
DLUD1 does not turn ON within the specified time.
Section
PCU
Case 1
Cause
DLUD1 sensor trouble, tray 1 lift-up motor trouble,
desk PWB, lift-up unit, paper feed unit harness
connection trouble
desk PWB, lift-up unit, paper feed unit harness
connection trouble
Check and
remedy
remedy
Check DLUD1 and its harness and connector.
Check the lift-up unit.
Check the lift-up unit.
Trouble content
DLUD2 does not turn ON within the specified time.
Section
PCU
Case 1
Cause
DLUD2 sensor trouble, tray 2 lift-up motor trouble,
desk PWB, lift-up unit, paper feed unit harness
connection trouble
desk PWB, lift-up unit, paper feed unit harness
connection trouble
Check and
remedy
remedy
Check DLUD2 and its harness and connector.
Check the lift-up unit.
Check the lift-up unit.
Trouble content
Desk transport motor operation trouble
Section
PCU
Case 1
Cause
Motor lock, motor RPM abnormality, overcurent to
the motor, console finisher control PWB trouble
the motor, console finisher control PWB trouble
Check and
remedy
remedy
Use SIM 4-3 to check the operation of the desk
transport motor.
transport motor.
Trouble content
Detection of desk connection incompatible with the
MX-1800
MX-1800
Section
PCU
Case 1
Cause
Connection of a desk which is incompatible with
the MX-1800 is detected.
the MX-1800 is detected.
Check and
remedy
remedy
Connect the MX-DEX1/DEX2.
Trouble content
CPT-ASIC access error (When the ASIC does not
operate normally.)
operate normally.)
Section
Scanner
Case 1
Cause
CPT-ASIC abnormality, SCU PWB abnormality
Check and
remedy
remedy
Turn OFF/ON the power several times. If the
trouble still occurs, replace the SCU PWB or the
CPT-ASIC.
trouble still occurs, replace the SCU PWB or the
CPT-ASIC.
Trouble content
Communication error between SCU and DOCC
Communication line test error when turning on the
power or after canceling an exclusion simulation.
Communication line test error when turning on the
power or after canceling an exclusion simulation.
Section
Scanner
Case 1
Cause
Connector or harness connection error or
disconnection
disconnection
Check and
remedy
remedy
Check the connector and harness in the
communication line.
communication line.
Case 2
Cause
Control PWB (SCU) trouble, DOCC PWB trouble.
Check and
remedy
remedy
Replace the SCU PWB or the DOCC PWB.
Case 3
Cause
Malfunction due to electrical noises.
Check and
remedy
remedy
Turn OFF/ON the power to electrical cancel the
trouble.
trouble.