MX-1800N (serv.man16). Section 8 - Self Diagnostics Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 21

Read Sharp MX-1800N (serv.man16) Service Manual online

MX-1800N  SELF DIAG AND TROUBLE CODE  8 – 21
 
L3-00
Mirror return trouble 
 
L4-02
Paper feed motor lock trouble
 
L4-04
Developing motor trouble (BLACK)
 
L4-05
Developing motor trouble (COLOR)
 
L4-06
Transfer belt separation position 
sensor trouble
 
L4-11
Shift motor trouble
 
L4-30
Controller fan/HDD fan motor trouble
 
L4-31
Paper exit cooling fan trouble
 
L4-32
Power cooling fan/ozone exhaust fan
trouble
Trouble content
Mirror return is not completed within the specified 
time.
Section
Scanner
Case 1
Cause
Mirror unit trouble, mirror wire disengagement
Check and 
remedy
Use SIM1-1 to check the mirror operation.
Trouble content
When the paper feed motor is rotated in warming 
up or in canceling a jam and the lock signal is not 
detected within 1sec.
Section
PCU
Case 1
Cause
Paper feed motor trouble, harness connection 
trouble between PCU PWB and paper feed motor, 
control circuit trouble
Check and 
remedy
Use SIM6-1 to check the paper feed motor 
operation. Check the harness and the connector 
between the PCU PWB and the paper feed motor.
Trouble content
The motor lock signal is detected during rotation of 
the developing motor.
Section
PCU
Case 1
Cause
Harness connection trouble between the PCU 
PWB and the developing motor.
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the developing motor.
Case 2
Cause
Developing motor trouble, control circuit trouble
Check and 
remedy
Use SIM25-1 to check the operation of the 
developing motor.
Trouble content
The motor lock signal is detected during rotation of 
the developing motor.
Section
PCU
Case 1
Cause
Harness connection trouble between the PCU 
PWB and the developing motor.
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the developing motor.
Case 2
Cause
Developing motor trouble, control circuit trouble
Check and 
remedy
Use SIM25-1 to check the operation of the 
developing motor.
Trouble content
When separating the primary transfer belt unit, 
change in the separation position sensor 
characteristics is not detected within the specified 
time.
Section
PCU
Case 1
Cause
Harness connection trouble between the PCU 
PWB and the separation position sensor
Check and 
remedy
Check the harness between the PCU PWB and the 
separation position sensor.
Case 2
Cause
The belt position sensor is not interrupted or it is 
always interrupted. Belt separation clutch 
operation trouble
Check and 
remedy
Use SIM6-3 to check the belt separation operation.
Case 3
Cause
The primary transfer belt unit is not installed.
Check and 
remedy
Install the primary transfer belt.
Trouble content
When the shift motor is initialized, no 
characteristics change of the shifter home position 
sensor is not detected within the specified time.
Section
PCU
Case 1
Cause
Shift motor trouble
Check and 
remedy
Use SIM6-1 to check the operation of the shift 
motor.
Case 2
Cause
Harness connection trouble between the PCU 
PWB and the shift motor, control circuit trouble
Check and 
remedy
Use SIM30-1 to check the shifter home position 
sensor. Check the harness and the connector 
between the PCU PWB and the shift motor.
Case 3
Cause
When the finisher is installed with the finisher 
connector disconnected and when the finisher 
communication trouble occurs.
Check and 
remedy
Connect the finisher connector.
When the communication trouble occurs between 
the PCU and the finisher, refer to the content of F1-
00.
Trouble content
1)
The motor lock signal is detected during 
rotation of the controller fan motor.
2)
The motor lock signal is detected during 
rotation of the HDD fan motor.
Section
MFP
Case 1
Cause
Fan motor trouble
Check and 
remedy
Use SIM6-2 to check the operation of the fan 
motor.
Case 2
Cause
Harness connection trouble between the mother 
PWB and the fan motor.
Check and 
remedy
Check the harness and the connector between the 
mother PWB and the fan motor.
Case 3
Cause
Control circuit trouble
Check and 
remedy
Replace the controller PWB.
Case 4
Cause
Mother PWB trouble.
Check and 
remedy
Replace the mother PWB.
Trouble content
When the paper exit cooling fan is operated, the 
fan operation signal is not detected within the 
specified time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is rotation 
actually.
Trouble content
When the power cooling fan/ozone exhaust fan is 
operated, the fan operation signal is not detected 
within the specified time.
Section
PCU
Case 1
Cause
Power cooling fan or ozone exhaust fan connector 
disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Page of 24
Display