Read Sharp AR-C270 (serv.man13) Service Manual online
Item
Display item
Low
High
Default
value
Description
A
PRINT PATTERN
1
21
1
Self print pattern
= 1
Gradation sub scanning direction (input process)
= 2
Gradation main scanning direction (input process)
= 3
Grid (input process)
= 4
Gradation pattern: 255, 0 – 254, increment of 1 gradation
= 5
Grid (Half tone)
= 6
Gradation sub scanning direction (Half tone): 16 steps, 16 intervals, 15 start
= 7
Gradation main scanning direction (Half tone): 16 steps, 16 intervals, 15 start
= 8
Equal pitch pattern sub scanning direction 1 by 4
= 9
Equal pitch pattern main scanning direction 1 by 4
=10
Equal pitch pattern sub scanning direction 2 by 6
=11
Equal pitch pattern main scanning direction 2 by 6
=12
Gradation sub scanning direction (Half tone): 16 steps 2 intervals
=13
All surface (HT)
=14
Cross pattern (sub scanning direction)
=15
Cross pattern (main scanning direction)
=16
Black color print main scanning direction
=17
Black color 10% (A4, A4R) density print
=18
Dot print (input process)
=19
Gradation pattern: 255, 0 – 254, increment of 1 gradation, (Text 1
×
1)
=20
=21
For ICU monitor software setup PG (with input DMA start) (Not operating)
=22
Print lattice pattern (25 MHz)
B
DENSITY
1
255
255
Gradation level
C
MULTI COUNT
1
999
1
Self print quantity setting
D
EXPO:
1
11
1
Density mode
= 1
THROUGH
No process (through)
= 2
CHAR/PIC AUTO
Test/Printed Photo Auto
= 3
CHAR/PIC MANUAL
Text/Printed Photo Manual
= 4
CHAR/PRPIC AUTO
Text/Photo Auto
= 5
CHAR/PRPIC MANU
Text/Photo Manual
= 6
CHAR AUTO
Text Auto
= 7
CHAR MANUAL
Text manual
= 8
PRINT PIC
Printed Photo
= 9
PRINT PAPER
Photo
= 10
MAP
Map
= 11
STANDARD DITHA
E
PAPER:
1
6
3
Cassette selection
= 1
MANUAL
Manual paper feed
= 2
CAS1
Cassette 1
= 3
CAS2
Cassette 2 (Default)
= 4
CAS3
Cassette 3
= 5
CAS4
Cassette 4
= 6
LCC
LCC
F
DUPLEX
1
2
1
Duplex print select
= 1
NO
Single
= 2
YES
Duplex
8 – 34