[8] SIMULATION
(Diagnostics, setting, adjustment value
input, data display)
1. Outline and purpose
There are the following simulation functions to check the machine
operations, troubleshoot, find causes, make various settings,
improves adjustment work speeds and serviceability. 
1) Various adjustments
2) Specification and function setting
3) Trouble cancel
4) Operation check
5) Counters check, setting, clear
6) Machine operation conditions (operation history) data check, clear
7) Transmission of various data (adjustment, setting, operations,
counter, etc.)
The operating procedures and displays slightly differ from the form of
the machine operation panel.
The typical forms are as follows:
1) Code system: Values input and mode selection are made with the
10-key pad and various function keys. 
2) Switch system: Simulation mode selection is made by combination
of switch setting. 
3) Values and mode selection is made with various function keys. As
a special one, a jumper wire is used to connect the check points
on the PWB to select the desired mode. 
2. Code system simulation 
A. Operating procedures and operations
Entering the simulation mode
1) Program (P) key 
 Interrupt key 
 Clear key 
 Interrupt key
(The machine enters the standby mode for the simulation main
code.)
2) Enter the main code with 10-key pad. 
 Press START key.
3) Enter the sub code of with 10-keypad. 
 Press START key.
4) Select the mode and the item with the 1-key pad and the function
key. 
5) The machine enters the selected mode.
To start the simulation, press the START key or the function key.
To cancel the current simulation mode and to change the main
code and the sub code, press the interrupt key. 
1) Press the all clear key. 
The simulation mode is canceled and the machine returns to the
normal operation mode. 
8 – 1
YES
NO
NO
YES
YES
YES
NO
NO
NO
YES
NO
YES
YES
NO
NO
YES
YES
NO
Standby for entry of SIM
sub code
Enter SIM sub code with
the 10-key.
Press the START button.
Press the START button.
The display is made according
to the selected mode and the item.
START (Normal mode)
Press the Program (P) key.
Press the interrupt key.
Press the clear key.
Press the interrupt key.
Standby for entry of
SIM code.
Enter the main code of
SIM with the 10-key.
The main code of SIM
is displayed.
Press the START button.
Is there a sub code ?
Select the mode and the
item with the 10-key and
the function key.
Operation check ?
Operating conditions
check ?
Data clear ?
Adjustments
or setting (counter data
change) ?
Do you
want to change the
content ?
Enter the new setting and
adjustment values.
Press the interrupt key.
Press the START button.
Operation is made according
to the selected mode and item.
Press the START button.
The display is made according to
the selected some and the item.
Press the START button.
Press the START button.
Is it the same
simulation ?
Press the interrupt key.
Do you want
to perform another
simulation ?
Do you
want to end the
simulation ?
The changed content
is stored.
The simulation mode
is canceled.
Press the clear all key.
Operation is made according
to the selected mode and the item.
(Other modes)
The selected mode and
the item are cleared.
8 –  2
B. Simulation list
(1) Main/Sub
Code
Function (Purpose)
Purpose
Section
Item
Main
Sub
1
1
Used to check the operations of the scanner
unit and its control circuit.
Operation test/check
Optical (Image scanning)
Operation
2
Used to check the sensors and detectors in
the scanner section and the related circuits.
Operation test/check
Optical (Image scanning)
Operation
2
1
Used to check the operations of the RADF
unit and the control circuit. (The document
feed operation is repeatedly performed.)
(AR-C150/C250/C160/C270)
Operation test/check
ADF/RADF/UDH/SPF
Operation
2
Used to check the operations of the sensors
and detectors in the RADF unit and the
related circuits. (AR-C150/C250)
Operation test/check
ADF/RADF/UDH/SPF
Operation
3
Used to check the operations of the loads in
the RADF unit and the related circuits.
(AR-C150/C250/C160/C270)
Operation test/check
ADF/RADF/UDH/SPF
Operation
3
2
Used to check the operations of the loads in
the sorter/finisher and the related circuits.
(AR-C150/C250/C160/C270) 
Operation test/check
Sorter/Finisher
Operation
3
Used to check the operations of the loads in
the sorter/finisher and the related circuits.
(AR-C150/C250/C160/C270) 
Operation test/check
Sorter/Finisher
Operation
4
2
Used to check the operations of the sensors
and detectors in the large capacity tray and
the related circuit.
(AR-C150/C250/C160/C270)
Operation test/check
Paper transport
Operation
3
Used to check the operations of the loads in
the large capacity tray and the control circuit.
(AR-C150/C250/C160/C270)
Operation test/check
Paper transport
Operation
5
1
Used to check the operations of the
operation panel display lamps and LCD and
the control circuit.
Operation test/check
Operation (Display/
Operation key)
Operation
2
Used to check the operations of the heater
lamp and the control circuit.
Operation test/check
Fixing (Fusing)
Operation
3
Used to check the operations of the scanner
lamp and the control circuit.
Operation test/check
Optical (Image scanning)
Operation
4
Used to check the operations of the
discharge lamp and the control circuit.
Operation test/check
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Others
Operation
6
1
Used to check the operations of the loads
(clutches and solenoids) in the paper
transport system and the control circuits.
Operation test/check
Paper transport
(Discharge/Switchback/
Transport)
Operation
2
Used to check the operation of each fan
motor and its control circuit.
Operation test/check
Others
Operation
7
1
Used to set the aging conditions.
Setting/
Operation test/check
Operation
6
Used to set the intermittent aging cycle.
Setting/
Operation test/check
Operation
8
Used to set Yes/No of warm-up time display.
Setting/
Operation test/check
Operation
9
Used to check the operation of each color
image quality.
Operation test/check
Others
Picture quality
8
1
Used to check and adjust the operation of
each print mode developing bias voltage and
the control circuit.
Adjustment/
Operation test/check
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
2
Used to check and adjust the operation of
each print mode main charger grid voltage
and the control circuit.
Adjustment/
Operation test/check
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
6
Used to check and adjust the operation of
the transfer charger current and the control
circuit. (Old)
Adjustment/
Operation test/check
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Copy
9
1
Used to check the operation of the loads
(clutches and solenoids) in the duplex
section and the control circuit.
(AR-C150/C250/C160/C270)
Operation test/check
Duplex
Operation
2
Used to check the operation of the sensors
and detectors in the duplex section and the
control circuit. (AR-C150/C250/C160/C270)
Operation test/check
Duplex
Operation
8 –  3
Code
Function (Purpose)
Purpose
Section
Item
Main
Sub
9
4
Used to check the operation of the duplex
unit alignment plate and the control circuit.
(AR-C150/C250/C160/C270)
Operation test/check
Duplex
Operation
10
0
Used to check the operation of the toner
motor and the control circuit. (Note) Never
execute this simulation with toner in the toner
hopper. Otherwise extra toner will enter the
developing section, causing overtoner. Be
sure to remove the toner from the toner
hopper.
Operation test/check
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Developer/
Toner Hopper
Operation
14
0
Used to cancel self diag troubles H3, H4,
and H5. Inhibition of the color copy mode
operation is canceled.
Clear/Cancel (Trouble
etc.)
Trouble
Error
15
0
Used to cancel self diag trouble U6 (Large
capacity tray). (AR-C150/C250/C160/C270)
Clear/Cancel (Trouble
etc.)
Paper transport
Trouble
16
0
Used to cancel self diag trouble U2.
Clear/Cancel (Trouble
etc.)
Trouble
Error
17
0
Used to cancel self diag troubles PF (copy
inhibition command from the host computer).
Clear/Cancel (Trouble
etc.)
Communication unit
(TEL/LIU/MODEM etc.)
Trouble
Error
21
1
Used to set the maintenance cycle.
Setting
Specifications
Counter
22
1
Used to check the print count value in each
section and each operation mode. (Used to
check the maintenance timing.)
Operation data
output/Check
(Display/Print)
Counter
2
Used to check the total misfeed count and
the total trouble count. (If the misfeed count
is considerably great, it may be judged as
necessary to repair. By dividing this count by
the total count, the misfeed rate can be
obtained.)
Operation data
output/Check
(Display/Print)
Trouble
3
Used to check misfeed positions and the
misfeed count of each position. (If the
misfeed count is considerably great, it may
be judged as necessary to repair.) (Other
sections than RADF section)
Operation data
output/Check
(Display/Print)
Trouble
Misfeed
4
Used to check the total trouble (self diag)
history.
Operation data
output/Check
(Display/Print)
Trouble
5
Used to check the ROM version of each unit
(section).
Others
Software
6
Used to print the setting and adjustment data
list.
Operation data
output/Check
(Display/Print)
Operation
7
Used to display the key operator code. (Used
when the customer forgets the key operator
code.)
User data output/Check
(Display/Print)
Data
User data
8
Used to check the number of uses of the
staple, and the RADF.
(AR-C150/C250/C160/C270)
Operation data
output/Check
(Display/Print)
Counter
9
Used to check the number of uses (print
quantity) of each paper feed section.
Operation data
output/Check
(Display/Print)
Paper transport
Counter
10
Used to check the system configuration
(option, internal hardware).
(AR-C150/C250/C160/C270)
Operation data
output/Check
(Display/Print)
Specifications
Options
12
Used to check the misfeed positions and the
number (history) of misfeed at each position.
(If the misfeed count is considerably great, it
may be judged as necessary to repair.)
(AR-C150/C250/C160/C270)
Operation data
output/Check
(Display/Print)
ADF/RADF/UDH/SPF
Trouble
Misfeed
24
1
Used to clear the the misfeed counter, the
misfeed history, the trouble counter, and the
trouble history. (After completion of
maintenance, the counters are cleared.)
Data clear
Memory
Counter
2
Used to clear the data of the number of uses
(print quantity) of each paper feed section.
Data clear
Paper transport
Counter
Paper feed
3
Used to clear the data of the number of uses
of the stapler, the RADF, and the scanner.
Data clear
Counter
4
Used to reset the maintenance counter.
Data clear
Counter
Maintenance
5
Used to reset the developer counter. (The
developer counter of the installed DV unit is
reset.)
Data clear
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Developer/
Toner Hopper
Counter
Developer
8 –  4
Page of 34
Display

Download Sharp AR-C270 (serv.man13) Service Manual (Repair Manual)

Here you can read online and download Sharp AR-C270 (serv.man13) Service Manual in PDF. AR-C270 (serv.man13) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp AR-C270 (serv.man13) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.