AR-405. Cougar Handy Guide (Updated March'02) - Sharp Copying Equipment Handy Guide. Page 47

Read Sharp AR-405 Handy Guide online

 
TECHNICAL UPDATE 
 
SHARP ELECTRONICS (UK) LTD 
DOCUMENT SYSTEMS GROUP
 
47 
VERSION 1C 
MARCH 2002
 
 
 
 
 
         ERROR CODE 
Model 
Fault 
Advice 
Cougar 2k 
CE-02 
Server not found. Check IP address of E-Mail or FTP server. 
 (AR-NS1) 
All 
C1-00 
Main Charge “Arching” – check MC grid is installed and fitted 
correctly. Also check HVU output. 
All 
E7-XX 
Various E7 codes can occur if the ICU “Cooling” fan has not been 
reconnected following the removal of the ICU upper cover. 
All 
E7-00 
Poor contact on PCU flashcard. Clean and re-install. 
Also check the MC corona unit has been inserted correctly (MC 
“arching” can cause E7 following a warming up message). 
 
Ensure the TC Earth strap has not been damaged due to broken 
lift angle (rear frame). Also check for waste toner contamination 
of the MC & TC end blocks and connections. 
AR280/285/
335 
E7-00 
Intermittent E7-00 is corrected by the following firmware revision:- 
ICU – 3.37, PCU – 3.35, OPE 3.35 or higher. 
All 
E7-01 
Image data memory trouble :- 
1.  The ICU Simm card is not installed. 
2.  Faulty ICU Simm card. 
3.  ICU PWB abnormality. 
4.  The Simm capacity is insufficient for the model. 
AR280/285/
335 
E7-03 
Fit HDD protective sheet 
(PSHEZ4685FCZZ) 
to eliminate HDD 
vibration. Can also cause E7-11. 
Also, ensure engine firmware is v2.02 or higher (All). 
All 
E7-11 
Check FFC1/FFC2 CCD harnesses for poor connection. Ensure 
the optical mirror base is not skewed. 
 
Also check copy lamp operation during power on for CCD 
shading correction – replace lamp if necessary (not 
AR280/285/335). 
Not 
AR505/507 
F1-05 
Incorrect timing operation of AS & PLS sensors. Check both 
sensors initialise when the off-set tray reaches home position by 
using Sim 3. Check the cam detection lever is fitted correctly or 
not broken. (AR-FN2) 
All 
F1-08 
STUHP sensor not working. Check sensor and connection CN-J 
on the finisher control pwb. 
Not 
AR505/507 
F1-11 
Incorrect fitting of the offset tray jamming the bundle discharge 
rollers as they rotate 360 degrees after the off set tray reaches 
home. (AR-FN2). 
Not 
AR505/507 
F1-14 
F1-15 
Check the finisher is level – on loose or flexible flooring, the 
finisher can move away from the machine for small periods. 
When this happens, and error will occur due to the movement of 
the off-set tray. (AR-FN2) 
AR505/507 
F1-18 
The lower output tray paddle roller becomes tight. Strip, remove 
and lubricate the brass bearings and the shaft. 
Page of 54