Read Sharp AR-405 Handy Guide online
TECHNICAL UPDATE
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS GROUP
50
VERSION 1C
MARCH 2002
PERIPHERALS
Model
Fault
Advice
AR-FN2
“Check finisher cover” message.
Incorrect fitting of locating pin or poor
finisher alignment. Adjust finisher
height. (also check ULS2 operation).
finisher alignment. Adjust finisher
height. (also check ULS2 operation).
AR-FN2
Corruption of image data or “Bar
Coded” copies.
Coded” copies.
Check AR-FN2 for static electricity
interfering with 5/24v.
Fit modified earth plates :- PG9/17
interfering with 5/24v.
Fit modified earth plates :- PG9/17
0CW4090P060//
and PG10/55
0CW4090P061//
(fitted as standard
from March’99).
AR-LC1
LCC locked out – enable to open.
Reset with Sim 15.
Click on the first or last page to see other AR-405 service manuals if exist.