IC22 Re Initialise Procedure
Detailed below is a procedure on how to reset machine data due to IC22 replacement or
failure (corruption). Refer to the “Parts Compatibility” section for IC22 machine compatibility.
Where possible, execute Simulation 22-06 (Data Print) for meter reading and machine
set-up information etc prior to re-initialising.
failure (corruption). Refer to the “Parts Compatibility” section for IC22 machine compatibility.
Where possible, execute Simulation 22-06 (Data Print) for meter reading and machine
set-up information etc prior to re-initialising.
NOTE:
For AR287/337/407 and 507 models with an AR-NS1 installed, a
replacement IC22 must be obtained via the EEprom exchange service
from TPM Group.
replacement IC22 must be obtained via the EEprom exchange service
from TPM Group.
The AR-NS1 cannot be reactivated following the execution of this
procedure as the Product Key is linked to the machine serial number,
which is erased.
procedure as the Product Key is linked to the machine serial number,
which is erased.
Procedure:
1.
Remove IC22 and Power On the Copier - A U2 Trouble Code should be
displayed.
displayed.
2. Enter
Simulation 80-09 (Initial Data Setting) but DO NOT execute.
3.
Carefully Insert IC22 (with the copier still powered on).
4. Now
Execute
Simulation 80-09 to reprogram the EEProm with the Initial
Data.
5.
Power cycle the copier & Execute Simulation 16 to clear “U2” trouble.
6. Execute
Simulations 89-01 and 89-02 to clear all counters and key
operator data. Also use Simulation 24-01 to clear trouble/jam history
counters.
counters.
7. Execute
Enter
Simulation 26-59 (Scan Motor Set-up) to correct L3-00
trouble code - Set either “2 or 3” for 2 or 3 phase motor respectively.
AR287, 337, 407 or 507 models only
AR287, 337, 407 or 507 models only
8.
Re-enter the Toner Density Value by using Simulation 80-02 or
Simulation 25-02 (recycling the developer).
Simulation 25-02 (recycling the developer).
9.
Re configure the SCSI port set-up using Simulation 26-44.
10. Change
Simulation 26-06 to “UK Destination” and check “UK English”
language set-up within Simulation 26-22.