Read Sharp AR-405 Handy Guide online
TECHNICAL UPDATE
SHARP ELECTRONICS (UK) LTD
DOCUMENT SYSTEMS GROUP
43
VERSION 1C
MARCH 2002
PAPER FEED
Model
Fault
Advice
All
Jam reset procedure.
1.Open lower RT Side door
2.Close lower RT Side door
3.Open front cabinet & remove jam
4.Close front cabinet
5.Open delivery unit for more than
three seconds
6.Close delivery unit.
2.Close lower RT Side door
3.Open front cabinet & remove jam
4.Close front cabinet
5.Open delivery unit for more than
three seconds
6.Close delivery unit.
All
Corrugated copy on last 2/3 of A3
page.
page.
Seized lower fuser roller bearings –
replace.
replace.
All
Z Folding
Transport clutches contaminated with
grease. Fit additional brake spring
grease. Fit additional brake spring
(MSPRP1881FCZ1)
to transport roller
and adjust Sim 51-02 (see Bulletin
071). Replace transport clutches if Z-
folding persists.
071). Replace transport clutches if Z-
folding persists.
All
POD1 misfeeds.
Paper jams at large white pressure
rollers after DGS sensor. Attach
additional mylars to guide paper into
the nip of rollers.
rollers after DGS sensor. Attach
additional mylars to guide paper into
the nip of rollers.
All
POD2_N/NR misfeeds when using
duplex mode.
duplex mode.
Warped “Turn Over” paper guide. Fit
modified guide
modified guide
PGIDM1819FCZ1.
Also check for worn TC guide
(CGIDH1781FC51)
and the TC earth
spring is not missing
.
If toner build up is evident on paper
guide, also check Doctor Blade setting
on DV unit.
guide, also check Doctor Blade setting
on DV unit.
All
Indents on paper after exiting.
Check spring tension on exit guide.
Remove exit springs when installing
AR-FN1 & FN2 only.
Remove exit springs when installing
AR-FN1 & FN2 only.
All
Unable to reset machine following a
paper jam.
paper jam.
High resistance in the main door
switches – replace.
Ensure the exterior covers are closed
in the correct order as per information
guide.
switches – replace.
Ensure the exterior covers are closed
in the correct order as per information
guide.
All
Duplex misfeeds and/or skewing.
Check duplex unit for cracks around
curl correction unit. Fit modified
support brackets (Bulletin 014):-
curl correction unit. Fit modified
support brackets (Bulletin 014):-
LPLTM5703FCZZ (Support Plate)
LPLTM5704FCZZ (Bearing
Reinforcement Plate)
CPLTM5705FC01 (Roller Support Plate)
LPLTM5704FCZZ (Bearing
Reinforcement Plate)
CPLTM5705FC01 (Roller Support Plate)
Click on the first or last page to see other AR-405 service manuals if exist.