IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
parts of material classified as V-0 or V-1
according to AS/NZS 60695.11.10 provided that
the sample tested was not thicker than the
relevant part.
according to AS/NZS 60695.11.10 provided that
the sample tested was not thicker than the
relevant part.
20.201.2.3 Testing by needle-flame test
If parts, other than enclosures, do not withstand
the glow wire tests of 20.201.2.2, by failure to
extinguish within 30 s after the removal of the
glow-wire tip, the needle-flame test detailed in
20.201.2.2 shall be made on all parts of non-
metallic material which are within a distance of 50
mm or which are likely to be impinged upon by
flame during the tests of 20.201.2.2. Parts
shielded by a separate barrier that meets the
needle-flame test shall not be tested.
the glow wire tests of 20.201.2.2, by failure to
extinguish within 30 s after the removal of the
glow-wire tip, the needle-flame test detailed in
20.201.2.2 shall be made on all parts of non-
metallic material which are within a distance of 50
mm or which are likely to be impinged upon by
flame during the tests of 20.201.2.2. Parts
shielded by a separate barrier that meets the
needle-flame test shall not be tested.
NOTE 1 - If the enclosure does not withstand the
glow-wire test the appliance is considered to
have failed to meet the requirements of Clause
21.201 without the need for consequential
testing.
glow-wire test the appliance is considered to
have failed to meet the requirements of Clause
21.201 without the need for consequential
testing.
NOTE 2- If other parts do not withstand the glow-
wire test due to ignition of the tissue paper and if
this indicates that burning or glowing particles
can fall onto an external surface underneath the
apparatus, the apparatus is considered to have
failed to meet the requirements of Clause 21 .201
without the need for consequential testing
wire test due to ignition of the tissue paper and if
this indicates that burning or glowing particles
can fall onto an external surface underneath the
apparatus, the apparatus is considered to have
failed to meet the requirements of Clause 21 .201
without the need for consequential testing
NOTE 3 - Parts likely to be impinged upon by the
flame are considered to be those within the
envelope of a vertical cylinder having a radius of
10 mm and a height equal to the height of the
flame , positioned above the point of the material
supporting, in contact with, or in close proximity
to, connections.
flame are considered to be those within the
envelope of a vertical cylinder having a radius of
10 mm and a height equal to the height of the
flame , positioned above the point of the material
supporting, in contact with, or in close proximity
to, connections.
20.201.2.4 Testing of printed boards
The base material of PRINTED BOARDS shall be
subject to the needle-flame test of Clause
21.201.2.3. The flame shall be applied to the
edge of the board where the heats ink effect is
lowest when the board is positioned as in normal
use. The flame shall not be applied to an edge
consisting of broken perforations, unless the
edge is less than 3 mm from a POTENTIAL
IGNITION SOURCE.
subject to the needle-flame test of Clause
21.201.2.3. The flame shall be applied to the
edge of the board where the heats ink effect is
lowest when the board is positioned as in normal
use. The flame shall not be applied to an edge
consisting of broken perforations, unless the
edge is less than 3 mm from a POTENTIAL
IGNITION SOURCE.
The test is not carried out if the
- PRINTED BOARD does not carry any
potential ignition source;
- base material of PRINTED BOARDS, on
which the available power at a connection
exceeds 15 VA operating at a voltage
exceeding 50 V and equal or less than 400 V
exceeds 15 VA operating at a voltage
exceeding 50 V and equal or less than 400 V