Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
(peak) a.c. or d.c. under normal operating 
conditions, is of flammability category V-1 or 
better according to AS/NZS 60695.11.10, or 
the PRINTED BOARDS are protected by an 
enclosure meeting the flammability category 
V-0 according to AS/NZS 60695.11.10, or 
made of metal, having openings only for 
connecting wires which fill the openings 
completely; or 
-  base material of PRINTED BOARDS, on 
which the available power at a connection 
exceeds 15 VA operating at a voltage 
exceeding 400 V (peak) a.c. or d.c. under 
normal operating conditions, and base 
material of PRINTED BOARDS supporting 
spark gaps which provides protection against 
overvoltages, is of flammability category V-0 
according to AS/NZS 60695.11 .10 or the 
PRINTED BOARDS are contained in a metal 
enclosure, having openings only for 
connecting wires which fill the openings 
completely. 
Compliance shall be determined using the 
smallest thickness of the material. 
NOTE- Available power is the maximum power 
which can be drawn from the supplying circuit 
through a resistive load whose value is chosen to 
maximize the power for more than 2 min when 
the circuit supplied is disconnected. 
20.201.3 For open circuit voltages greater 
than 4 kV 
POTENTIAL IGNITION SOURCES with open 
circuit voltages exceeding 4 kV (peak) a.c. or d.c. 
under normal operating conditions shall be 
contained in a FIRE ENCLOSURE which shall 
comply with flammability category V-1 or better 
according to AS/NZS 60695.11.10. 
 