SUB 250P (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 108

Read JBL SUB 250P (serv.man2) EMC - CB Certificate online

 
Page 53 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
19.201.2 Restraining device 
19.201.2.1 Television receivers should be 
provided with a restraining device such as a fixing 
point to facilitate restraining the television from 
toppling forward. 
19.201.2.2 Where a restraining device is provided 
in accordance with 19.201.2.1 information shall 
be provided in the instructions for installation or 
use, to ensure correct and safe installation. Such 
information should also be provided as a label on 
the television receiver. Any such restraining 
device shall be capable of withstanding a pull of 
100 N in all directions without damage.  
19.201.3 Glass slide test ǂ 
Television receivers and display devices that may 
be used for television purposes, with a mass of 
18 kg or more, are placed on a clean, dry, glass 
covered horizontal surface such that only the 
supporting feet are in contact with the glass. The 
glass-covered surface is then tilted in the most 
unfavourable direction through an angle of 10°. 
During the tests, the equipment shall not slide. 
ǂ Clause 19.201.3 forms part of the Standard on 
31 January 2013. 
20 
Delete the following paragraph: 
'The requirements are considered to be fulfilled if 
the apparatus complies with the requirements of 
20.1 and 20.2' and replace with 
'The requirements are considered to be fulfilled if 
the apparatus complies with the requirements of 
20.1 and 20.2. Alternatively the requirements are 
considered to be fulfilled if the apparatus 
complies with the requirements of Clause 
20.201.' 
 
N/A 
Table 21 
In the third and fourth columns delete ' HB75' and 
'No requirement' and replace both with 'V-1 '. 
 
N/A 
20.2.3 
After Clause 20.2.3, add the following variation: 
20.201 Resistance to fire-Alternative tests 
20.201.1 General 
Parts of non-metallic material shall be resistant to 
ignition and the spread of fire. 
This requirement does not apply to decorative 
trims, knobs and other parts unlikely to be ignited 
or to propagate flames originating from inside the 
apparatus, or the following: 
a) Components that are contained in an 
enclosure having a flammability category of V-0 
according to AS/NZS 60695.11.10 and having 
openings only for the connecting wires filling the 
 
N/A 
Page of 112
Display