IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
20.2.1
Fire enclosure required:
1) circuits and components where the available
power exceeds 15 W,
power exceeds 15 W,
2) inductors and windings conductively connected
to the mains, and
to the mains, and
3) high-voltage products.
P
20.2.1
The fire enclosure complies with the flammability
requirements of Table 22 according to UL 94 and
746C
requirements of Table 22 according to UL 94 and
746C
P
20.2.1
Reference to IEC 60695-11-10 or clause G.1 of
annex G replaced by UL 94 or UL 746C
annex G replaced by UL 94 or UL 746C
P
20.2.1
Table 22 - Flammability categories for fire
enclosures
enclosures
P
20.2.2
P
20.2.2
Compliance is checked by inspection and
measurement and using the articulated finger
probe, figure 18.
measurement and using the articulated finger
probe, figure 18.
P
20.2.3
Outer enclosures have a minimum flammability
rating of HB when an internal fire enclosure is
provided
rating of HB when an internal fire enclosure is
provided
N/A
A
Apparatus intended for outdoor use or for wet
locations has any of the following attributes:
locations has any of the following attributes:
a) provided with a means to be transportable,
b) has a mass less than 35 kg,
c) can be battery operated, or
d) associated literature states or implies such use
N/A
A
An apparatus as described in a), b), or c) above
that is marked as specified in 5.4.1 a) is not
intended for outdoor or wet location use
that is marked as specified in 5.4.1 a) is not
intended for outdoor or wet location use
N/A
A
Apparatus permanently installed outdoors is
considered to be for permanent outdoor use
considered to be for permanent outdoor use
N/A
A.5
Clauses A.5, A.5.1 and A.5.4.1 are deleted
N/A
A.9.1.1
Touch current test after the water spray test
described in A.11.1.1
described in A.11.1.1
N/A
A.10
Clauses A.10, A.10.2 and A.10.2.1-2 are deleted
N/A
A.11.1.1
Clauses A.10, A.10.2 and A.10.2.1-2 are deleted
N/A
A.16.1
Flexible cords are suitable for outdoor use
N/A
A.20.2.1
Enclosures for an apparatus intended for
permanent outdoor location comply with
requirements for Type 3 enclosures in UL 50
permanent outdoor location comply with
requirements for Type 3 enclosures in UL 50
N/A
B
IEC 62151 Clause 4 applies except for 4.1.2,
4.1.3, 4.2.1.1 and 4.2.1.2
4.1.3, 4.2.1.1 and 4.2.1.2
N/A
B
The requirements of 4.2.1.1 are replaced by the
N/A