SUB 250P (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 104

Read JBL SUB 250P (serv.man2) EMC - CB Certificate online

 
Page 49 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
20.2.1 
Fire enclosure required: 
1) circuits and components where the available 
power exceeds 15 W, 
2) inductors and windings conductively connected 
to the mains, and 
3) high-voltage products. 
 
20.2.1 
The fire enclosure complies with the flammability 
requirements of Table 22 according to UL 94 and 
746C 
 
20.2.1 
Reference to IEC 60695-11-10 or clause G.1 of 
annex G replaced by UL 94 or UL 746C 
 
20.2.1 
Table 22 - Flammability categories for fire 
enclosures 
 
20.2.2 
 
20.2.2 
Compliance is checked by inspection and 
measurement and using the articulated finger 
probe, figure 18. 
 
20.2.3 
Outer enclosures have a minimum flammability 
rating of HB when an internal fire enclosure is 
provided 
 
N/A 
Apparatus intended for outdoor use or for wet 
locations has any of the following attributes: 
a) provided with a means to be transportable, 
b) has a mass less than 35 kg, 
c) can be battery operated, or 
d) associated literature states or implies such use 
 
N/A 
An apparatus as described in a), b), or c) above 
that is marked as specified in 5.4.1 a) is not 
intended for outdoor or wet location use 
 
N/A 
Apparatus permanently installed outdoors is 
considered to be for permanent outdoor use 
 
N/A 
A.5 
Clauses A.5, A.5.1 and A.5.4.1 are deleted 
 
N/A 
A.9.1.1 
Touch current test after the water spray test 
described in A.11.1.1 
 
N/A 
A.10 
Clauses A.10, A.10.2 and A.10.2.1-2 are deleted 
 
N/A 
A.11.1.1 
Clauses A.10, A.10.2 and A.10.2.1-2 are deleted 
 
N/A 
A.16.1 
Flexible cords are suitable for outdoor use 
 
N/A 
A.20.2.1 
Enclosures for an apparatus intended for 
permanent outdoor location comply with 
requirements for Type 3 enclosures in UL 50 
 
N/A 
IEC 62151 Clause 4 applies except for 4.1.2, 
4.1.3, 4.2.1.1 and 4.2.1.2 
 
N/A 
The requirements of 4.2.1.1 are replaced by the 
 
N/A 
Page of 112