Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
insulating material which are within a distance of 
3 mm of the connection. 
NOTE - Contacts in components such as switch 
contacts are considered to be connections. 
For parts which withstand the glow-wire test but 
produce a flame, other parts above the 
connection within the envelope of a vertical 
cylinder having a diameter of 20 mm and a height 
of 50 mm shall be subjected to the needle flame 
test. However, parts shielded by a barrier which 
meets the needle-flame test need not be tested. 
The needle-flame test shalt be made in 
accordance with AS/NZS 60695.11.5 with the 
following modifications: 
Clause of 
AS/NZS 
60695.11.5 
Change 
9 Test 
Procedure 
 
9.2 
Applicatio
n of 
needle-
flame 
Replace the second sentence of 
the first paragraph with: 
The specimen shall be arranged 
so that the flame can be applied 
t o a vertical or horizontal edge 
as shown in the examples of 
figure 1. 
Add to the end of the first 
paragraph: 
If possible, the flame shall be 
applied at least 10 mm from a 
corner. 
Replace the second paragraph 
with: 
The duration of application of the 
test flame shalt be 30 ±1 s. 
9.3 
Number of 
specimens 
Replace with: 
The test shall be made on one 
specimen. If the specimen does 
not withstand the test, the test 
may be repeated on two further 
specimens, both of which shall 
then withstand the test 
11 
Evaluation 
of test 
results 
Replace with: 
The duration of burning (tb} shall 
not exceed 30 s. However, for 
printed circuit boards, it shall not 
exceed 15 s. 
The needle-flame test shall not be carried out on 