Read JBL SUB 250P (serv.man2) EMC - CB Certificate online
Page 48 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
to be conducted before and after the sub-clause
12.1.5 stress relief test.
12.1.5 stress relief test.
19.1
References to an apparatus in combination with a
supplied cart or recommended stand are deleted
supplied cart or recommended stand are deleted
N/A
19.2
References to an apparatus in combination with a
supplied cart or recommended stand are deleted
supplied cart or recommended stand are deleted
N/A
19.2.1
Glass Slide test
N/A
19.3
Horizontal force stability test using Table 20A
values from UL 60065
values from UL 60065
N/A
19.5
Reference to the impact hammer in the first
compliance paragraph is deleted
compliance paragraph is deleted
N/A
19.6.
Includes Equipment rack mounting test
N/A
20.1a
Delete
N/A
20.1b
Exception for parts such as protection TV lenses,
loudspeaker parts, external accessories, and
fibrous materials
loudspeaker parts, external accessories, and
fibrous materials
N/A
Reference to IEC 60695-11-10 is replaced by UL
94
94
N/A
20.1.2
Sleeving, extruded tubing and insulation on wiring
are rated VW-1:
are rated VW-1:
a) wiring located in a circuit that is considered a
potential ignition source, or
potential ignition source, or
b) wiring not located in a circuit that is a potential
ignition source but is in contact with wiring located
in a circuit that is a potential ignition source
ignition source but is in contact with wiring located
in a circuit that is a potential ignition source
P
Tape in contact with parts of circuits that are
potential ignition sources is flame retardant
potential ignition sources is flame retardant
P
20.1.3
Printed wiring boards, on which the available
power as the connection exceeds 15 W or the
operating voltage exceeds 50 V a.c. or d.c under
normal operating conditions, is of flammability
category V-1 or better
power as the connection exceeds 15 W or the
operating voltage exceeds 50 V a.c. or d.c under
normal operating conditions, is of flammability
category V-1 or better
P
Reference to IEC 60695-11-10 replaced by UL 94
P
Exception for printed boards housed in metal
enclosures is deleted
enclosures is deleted
N/A
Option to use Clause G.1 of Annex G is deleted
N/A
20.1.4
Components and parts comply with the relevant
flammability category according to UL 94 as
specified in table 21
flammability category according to UL 94 as
specified in table 21
P
20.1.4
Component power supplies complying with UL
1310, UL 1950 Third Edition, UL 60950, or UL
60950-1 fulfill the clause
1310, UL 1950 Third Edition, UL 60950, or UL
60950-1 fulfill the clause
N/A
20.1.4
Table 21 - Flammability categories for components
and parts
and parts
N/A
Click on the first or last page to see other SUB 250P (serv.man2) service manuals if exist.