SUB 250P (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 109

Read JBL SUB 250P (serv.man2) EMC - CB Certificate online

 
Page 54 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
openings completely, and for ventilation not 
exceeding 1 mm in width regardless of length. 
b) The following parts which would contribute 
negligible fuel to a fire: 
- small mechanical parts, the mass of which does 
not exceed 4 g, 
- such as mounting parts, gears, cams, belts and 
bearings; 
small electrical components, such as capacitors 
with a volume not exceeding 1750 mm
3
integrated circuits, transistors and optocoupler 
packages, if these components are mounted on 
material of flammability category V-1 or better 
according to AS/NZS 60695.11.10. 
NOTE - In considering how to minimize 
propagation of fire and what 'small parts' are, 
account should be taken of the cumulative effect 
of small parts adjacent to each other for the 
possible effect of propagating fire from one part 
to another. 
Compliance shall be checked by the tests of 
20.201.2.1, 20.201.2.2. and 20.201.2.3 
For the base material of PRINTED BOARDS, 
compliance shall be checked by the test of 
20.201.2.4.  
The tests shall be carried out on parts of non-
metallic material which have been removed from 
the apparatus. When the glow-wire test is carried 
out, they are placed in the same orientation as 
they would be in normal use. 
These tests are not carried out on internal wiring. 
20.201.2 Tests 
20.201.2.1 Testing of non-metallic parts 
Part of non-metallic material shall be subject to 
the glow-wire test of AS/NZS 60695.2.11 which 
shall be carried out at 550°C. 
Parts for which the glow-wire test cannot be 
carried out, such as those made of soft or foamy 
material, shall meet the requirements specified in 
ISO 9772 for category FH-3 material. The glow-
wire test shall not be carried out on parts of 
material classified at least FH-3 according to ISO 
9772 provided that the sample tested was not 
thicker than the relevant part.  
20.201.2.2 Testing of insulated parts 
Part of insulating material supporting 
POTENTIAL IGNITION SOURCES shall be 
subject to the glow-wire test of AS/NZS 
60695.2.11 which shall be carried out at 750°C. 
The test shall be also carried out on other parts of 
Page of 112
Display

Click on the first or last page to see other SUB 250P (serv.man2) service manuals if exist.