Read JBL SUB 250P (serv.man2) EMC - CB Certificate online
Page 54 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
openings completely, and for ventilation not
exceeding 1 mm in width regardless of length.
exceeding 1 mm in width regardless of length.
b) The following parts which would contribute
negligible fuel to a fire:
negligible fuel to a fire:
- small mechanical parts, the mass of which does
not exceed 4 g,
not exceed 4 g,
- such as mounting parts, gears, cams, belts and
bearings;
bearings;
small electrical components, such as capacitors
with a volume not exceeding 1750 mm
with a volume not exceeding 1750 mm
3
,
integrated circuits, transistors and optocoupler
packages, if these components are mounted on
material of flammability category V-1 or better
according to AS/NZS 60695.11.10.
packages, if these components are mounted on
material of flammability category V-1 or better
according to AS/NZS 60695.11.10.
NOTE - In considering how to minimize
propagation of fire and what 'small parts' are,
account should be taken of the cumulative effect
of small parts adjacent to each other for the
possible effect of propagating fire from one part
to another.
propagation of fire and what 'small parts' are,
account should be taken of the cumulative effect
of small parts adjacent to each other for the
possible effect of propagating fire from one part
to another.
Compliance shall be checked by the tests of
20.201.2.1, 20.201.2.2. and 20.201.2.3
20.201.2.1, 20.201.2.2. and 20.201.2.3
For the base material of PRINTED BOARDS,
compliance shall be checked by the test of
20.201.2.4.
compliance shall be checked by the test of
20.201.2.4.
The tests shall be carried out on parts of non-
metallic material which have been removed from
the apparatus. When the glow-wire test is carried
out, they are placed in the same orientation as
they would be in normal use.
metallic material which have been removed from
the apparatus. When the glow-wire test is carried
out, they are placed in the same orientation as
they would be in normal use.
These tests are not carried out on internal wiring.
20.201.2 Tests
20.201.2.1 Testing of non-metallic parts
Part of non-metallic material shall be subject to
the glow-wire test of AS/NZS 60695.2.11 which
shall be carried out at 550°C.
the glow-wire test of AS/NZS 60695.2.11 which
shall be carried out at 550°C.
Parts for which the glow-wire test cannot be
carried out, such as those made of soft or foamy
material, shall meet the requirements specified in
ISO 9772 for category FH-3 material. The glow-
wire test shall not be carried out on parts of
material classified at least FH-3 according to ISO
9772 provided that the sample tested was not
thicker than the relevant part.
carried out, such as those made of soft or foamy
material, shall meet the requirements specified in
ISO 9772 for category FH-3 material. The glow-
wire test shall not be carried out on parts of
material classified at least FH-3 according to ISO
9772 provided that the sample tested was not
thicker than the relevant part.
20.201.2.2 Testing of insulated parts
Part of insulating material supporting
POTENTIAL IGNITION SOURCES shall be
subject to the glow-wire test of AS/NZS
60695.2.11 which shall be carried out at 750°C.
POTENTIAL IGNITION SOURCES shall be
subject to the glow-wire test of AS/NZS
60695.2.11 which shall be carried out at 750°C.
The test shall be also carried out on other parts of
Click on the first or last page to see other SUB 250P (serv.man2) service manuals if exist.