Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
 
 
The temperature of the flexible cord terminal is 
determined by means of melting particles, colour 
changing indicators or thermocouples, so chosen 
and positioned that they have negligible effect on 
the temperature being determined. 
Direct plug-in equipment. 
N/A 
 
The temperature rise of the terminals shall not 
exceed 45 K. 
 
J2.2.6.5 
Securement of pins (3112.2.13.9) 
 
 
Movement of pins (2.13.9.1) 
 
P  
 
Plugs shall be tested for pin movement by 
clamping the pin or pins not under test in a rigid 
holding block positioned 5 ±0.5 mm from the plug 
face and applying a force of 18±1 N to the pin 
under test. The design of the block shall be such 
that the pin under test shall not come into contact 
with the block during the test.  
 
 
Except for non-rewireable plugs, the test shall be 
carried out without a cord attached to the plug, 
and with the terminal screws loosened sufficiently 
to allow a 1mm
2
 conductor to be connected. 
 
N/A 
 
The plug and test equipment shall be 
preconditioned at a temperature of 40±1ºC for 1 
h, without the test force applied. Throughout the 
test, all parts of the plug and test equipment shall 
be maintained at this temperature. 
 
 
For all plugs, the point of application of the force 
of the plug along the pins, and the direction of the 
force shall be- 
a) in both directions along the line perpendicular 
to the plane of the pin, and passing through the 
centre of the pin; and  
b) in that plane in both directions along a line at 
right angles to that specified in Item(a). 
 
 
Over a period of 10 s, the force shall be gradually 
applied to each of the pins in the manner 
prescribed in Items (a) and (b), maintained at its 
maximum value for 10 s, and then released. The 
deflection of the pins shall be measured along the 
line of force relative to the face of the rigid holding 
block during the period when the force is applied. 
The maximum deflection shall not exceed 2.0 
mm. 
 