Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online
<12014238 001 >
Page 71 of 77
AS/NZS 3112 (Partial)
Clause
Requirement − Test
Result – Remark
Verdict
The temperature of the flexible cord terminal is
determined by means of melting particles, colour
changing indicators or thermocouples, so chosen
and positioned that they have negligible effect on
the temperature being determined.
determined by means of melting particles, colour
changing indicators or thermocouples, so chosen
and positioned that they have negligible effect on
the temperature being determined.
Direct plug-in equipment.
N/A
The temperature rise of the terminals shall not
exceed 45 K.
exceed 45 K.
P
J2.2.6.5
Securement of pins (3112.2.13.9)
P
Movement of pins (2.13.9.1)
P
Plugs shall be tested for pin movement by
clamping the pin or pins not under test in a rigid
holding block positioned 5 ±0.5 mm from the plug
face and applying a force of 18±1 N to the pin
under test. The design of the block shall be such
that the pin under test shall not come into contact
with the block during the test.
clamping the pin or pins not under test in a rigid
holding block positioned 5 ±0.5 mm from the plug
face and applying a force of 18±1 N to the pin
under test. The design of the block shall be such
that the pin under test shall not come into contact
with the block during the test.
P
Except for non-rewireable plugs, the test shall be
carried out without a cord attached to the plug,
and with the terminal screws loosened sufficiently
to allow a 1mm
carried out without a cord attached to the plug,
and with the terminal screws loosened sufficiently
to allow a 1mm
2
conductor to be connected.
N/A
The plug and test equipment shall be
preconditioned at a temperature of 40±1ºC for 1
h, without the test force applied. Throughout the
test, all parts of the plug and test equipment shall
be maintained at this temperature.
preconditioned at a temperature of 40±1ºC for 1
h, without the test force applied. Throughout the
test, all parts of the plug and test equipment shall
be maintained at this temperature.
P
For all plugs, the point of application of the force
of the plug along the pins, and the direction of the
force shall be-
of the plug along the pins, and the direction of the
force shall be-
a) in both directions along the line perpendicular
to the plane of the pin, and passing through the
centre of the pin; and
to the plane of the pin, and passing through the
centre of the pin; and
b) in that plane in both directions along a line at
right angles to that specified in Item(a).
right angles to that specified in Item(a).
P
Over a period of 10 s, the force shall be gradually
applied to each of the pins in the manner
prescribed in Items (a) and (b), maintained at its
maximum value for 10 s, and then released. The
deflection of the pins shall be measured along the
line of force relative to the face of the rigid holding
block during the period when the force is applied.
The maximum deflection shall not exceed 2.0
mm.
applied to each of the pins in the manner
prescribed in Items (a) and (b), maintained at its
maximum value for 10 s, and then released. The
deflection of the pins shall be measured along the
line of force relative to the face of the rigid holding
block during the period when the force is applied.
The maximum deflection shall not exceed 2.0
mm.