Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online
<12014238 001 >
Page 72 of 77
AS/NZS 3112 (Partial)
Clause
Requirement − Test
Result – Remark
Verdict
Following the test on all pins of a plug conforming
to Figure 2.1, any distortion 5 min after the
completion of the test on the last pin shall be such
that it will not prevent the plug from being inserted
in the appropriate standard gauges shown in
Appendix A, Appendix B and Appendix F without
the application of undue force.
to Figure 2.1, any distortion 5 min after the
completion of the test on the last pin shall be such
that it will not prevent the plug from being inserted
in the appropriate standard gauges shown in
Appendix A, Appendix B and Appendix F without
the application of undue force.
P
For other types of plugs, any distortion after 5 min
shall be such as will not prevent the plug being
inserted into an appropriate socket-outlet without
the application of undue force.
shall be such as will not prevent the plug being
inserted into an appropriate socket-outlet without
the application of undue force.
N/A
Fixing of pins (2.13.9.2)
P
A separate sample of a plug shall be heated to a
temperature of 50±20ºC for 1 h and maintained at
that temperature during the whole of tests,
including the 5 min period after removal of the test
load.
temperature of 50±20ºC for 1 h and maintained at
that temperature during the whole of tests,
including the 5 min period after removal of the test
load.
P
The plug shall be held firmly in such a manner
that there will be no undue squeezing or distortion
of the body, and the means of holding shall not
assist in maintaining the pins in their original
position,
that there will be no undue squeezing or distortion
of the body, and the means of holding shall not
assist in maintaining the pins in their original
position,
P
Each pin, in turn, shall have applied to it a force
which, over a period of 10 s, shall be increased
steadily to 60+0.6N and held at this value for 10
min.
which, over a period of 10 s, shall be increased
steadily to 60+0.6N and held at this value for 10
min.
P
Two tests on each pin shall be conducted, one
with the direction of force along the length of the
pin towards the body of the plug, and the other
with the direction of force along the length o f the
pin away from the body.
with the direction of force along the length of the
pin towards the body of the plug, and the other
with the direction of force along the length o f the
pin away from the body.
P
The attachment of pins shall be considered
inadequate if any pin is displaced relative to the
adjacent material of the body by more than 2.4
mm at any time during these tests, or if any pin
fails to return to within 0.8 mm of its nominal
length specified in Figure 2.1 within 5 min of the
removal of the test force,
inadequate if any pin is displaced relative to the
adjacent material of the body by more than 2.4
mm at any time during these tests, or if any pin
fails to return to within 0.8 mm of its nominal
length specified in Figure 2.1 within 5 min of the
removal of the test force,
P
J2.2.6.6
Additional tests for plugs with insulated pins
(3112.2.13.13)
(3112.2.13.13)
P
2.13.13 Additional tests on the insulation material
of insulated pin plugs
of insulated pin plugs
P
2.13.13.1 General
P