AS/NZS 3112 (Partial)
Clause
Requirement − Test
Result – Remark
Verdict
After this treatment and after recovery to room
temperature, the specimen shall be subjected to-
temperature, the specimen shall be subjected to-
a) the insulation resistance test in
accordance with CLAUSE 2.13.2(E);
b) high voltage test in accordance with
Clause 2.13.3 and;
c) abrasion test in accordance with Clause
2.13.13.6.
NOTE: At the manufacturer’s option, the same
sample may be used for this test and the low
temperature test (see Clause 2.13.13.4) and a
single abrasion test may be done.
sample may be used for this test and the low
temperature test (see Clause 2.13.13.4) and a
single abrasion test may be done.
P
(c) Low temperature test (2.13.13.4)
P
An insulated pin plug shall be maintained at –
15+2ºC for at least 24 h and returned to room
temperature.
15+2ºC for at least 24 h and returned to room
temperature.
P
The specimen shall be subjected to –
a) the insulation resistance test in
accordance with Clause 2.13.2(e);
b) high voltage test in accordance with
Clause 2.13.3 and;
c) abrasion test in accordance with Clause
2.13.13.6.
NOTE: At the manufacturer’s option, the same
sample may be used for this test and the static
damp heat test (see Clause 2.13.13.3) and a
single abrasion test may be done.
sample may be used for this test and the static
damp heat test (see Clause 2.13.13.3) and a
single abrasion test may be done.
P
(d) Impact test at low temperature (2.13.13.5)
P
A specimen of one insulated pin only shall be
subjected to an impact test by means of the
apparatus shown in Figure 2.6. The mass of the
falling weight shall be 100+1 g.
subjected to an impact test by means of the
apparatus shown in Figure 2.6. The mass of the
falling weight shall be 100+1 g.
P
The apparatus, on a sponge rubber pad 40 mm
thick, together with the specimen, shall be
maintained at –15+20ºC for at least 24 h.
thick, together with the specimen, shall be
maintained at –15+20ºC for at least 24 h.
P
At the end of this period, the specimen shall be
placed in position, as shown in Figure 2.6, and the
falling weight shall be allowed to fall from a height
of 100mm. Four impacts shall be applied
successively to the same specimen, rotating it
through 90º between impacts.
placed in position, as shown in Figure 2.6, and the
falling weight shall be allowed to fall from a height
of 100mm. Four impacts shall be applied
successively to the same specimen, rotating it
through 90º between impacts.
P