AS/NZS 3112 (Partial)
Clause
Requirement − Test
Result – Remark
Verdict
The pin shall not be broken off.
NOTE: Cracking of the pin, less than full
thickness, is not deemed to be broken off.
thickness, is not deemed to be broken off.
If in doubt pins shall be disassembled from the
plug and any insulation removed,
plug and any insulation removed,
NOTE: In some cases the break may be below
the face of the plug or the insulation may hold the
broken pieces together, retaining electrical
contact.
the face of the plug or the insulation may hold the
broken pieces together, retaining electrical
contact.
P
J2.2.6.4
Temperature rise test (3112.2.13.8)
The test current have been
specified and tested with the
integral adaptor.
specified and tested with the
integral adaptor.
P
2.13.8 Temperature rise test
P
Plugs shall be so constructed that they comply
with the following temperature rise test:
with the following temperature rise test:
a) Non-rewireable plugs are tested as
delivered (specially prepared sample with
access to terminals for temperature
measurement).
access to terminals for temperature
measurement).
b) Rewireable plugs are fitted with polyvinyl
chloride flexible cords with conductors
having the minimum cross-sectional area
specified in the manufacturers
instructions.
having the minimum cross-sectional area
specified in the manufacturers
instructions.
P
The terminal screws or nuts are tightened with a
torque equal to two-thirds of that specified in test
No.5.
torque equal to two-thirds of that specified in test
No.5.
NOTE: To ensure normal cooling of the terminals,
the conductors connected to plugs should have a
length of at least 1 m.
the conductors connected to plugs should have a
length of at least 1 m.
No screws or nuts used.
N/A
The test socket shall consist of a fixed socket
outlet of a type complying with this Standard.
outlet of a type complying with this Standard.
NOTE: In the case of a dispute, the test should be
repeated using a new socket outlet.
repeated using a new socket outlet.
Direct plug-in equipment.
N/A
The fixed socket outlet shall be mounted in an
appropriate metal-wall box installed in a draught
free position, and fitted with PVC insulated
conductors at least 2.5 m long, having nominal
cross-sectional areas as shown in Table 3.4.
appropriate metal-wall box installed in a draught
free position, and fitted with PVC insulated
conductors at least 2.5 m long, having nominal
cross-sectional areas as shown in Table 3.4.
Direct plug-in equipment.
N/A
The cables supplying the socket outlet shall be
enclosed for a distance of 1 m in conduit
terminated at the wall box.
enclosed for a distance of 1 m in conduit
terminated at the wall box.
Direct plug-in equipment.
N/A
The plug is inserted into the socket outlet and an
alternating current of 1.1 times rated current is
passed for 1 h.
alternating current of 1.1 times rated current is
passed for 1 h.
P