Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online
<12014238 001 >
Page 75 of 77
AS/NZS 3112 (Partial)
Clause
Requirement − Test
Result – Remark
Verdict
After the test the specimen shall be allowed to
return to room temperature and then examined,
No cracks of the insulating material shall be
visible with normal, or corrected to normal, vision
without additional magnification.
return to room temperature and then examined,
No cracks of the insulating material shall be
visible with normal, or corrected to normal, vision
without additional magnification.
NOTE: The cooling period of 14 h includes the
time necessary to cool down the apparatus.
time necessary to cool down the apparatus.
P
(e) Abrasion test (2.13.13.6)
P
An insulated pin of an insulated pin plug shall be
subjected to the following test by means of an
apparatus as shown in Figure 2.7.
subjected to the following test by means of an
apparatus as shown in Figure 2.7.
P
The test apparatus comprises a horizontally
disposed beam, which shall be pivoted about its
centre point. A short length of steel wire, 1 mm in
diameter and bent into a U-shape, the base of the
U being straight, shall be rigidly attached, at both
ends, to one end of the beam, so that the straight
part projects below the beam and shall be parallel
to the axis of the beam pivot.
disposed beam, which shall be pivoted about its
centre point. A short length of steel wire, 1 mm in
diameter and bent into a U-shape, the base of the
U being straight, shall be rigidly attached, at both
ends, to one end of the beam, so that the straight
part projects below the beam and shall be parallel
to the axis of the beam pivot.
P
The plug shall be held in a suitable clamp in such
a position that the straight part of the steel wire
rests on the major axis face of the plug pin, at
right angles to it. The pin shall slope downwards
at an angle of 10º to the horizontal.
a position that the straight part of the steel wire
rests on the major axis face of the plug pin, at
right angles to it. The pin shall slope downwards
at an angle of 10º to the horizontal.
P
The beam shall be loaded so that the wire exerts
a force of 4 N on the pin.
a force of 4 N on the pin.
P
The plug shall be moved backwards and forwards
in horizontal direction in the plane of the axis of
the beam, so that the wire rubs along the pin. The
length of the pin thus abraded shall be
approximately 9 mm, of which approximately 7
mm shall be over the insulation.
in horizontal direction in the plane of the axis of
the beam, so that the wire rubs along the pin. The
length of the pin thus abraded shall be
approximately 9 mm, of which approximately 7
mm shall be over the insulation.
P
The number of movement s shall be 20 000 (10
000 in each direction) and the rate of operation
shall be 30 movements per min.
000 in each direction) and the rate of operation
shall be 30 movements per min.
P
After the test, the pins shall show no damage
which may affect safety or impair the further use
of the plug, in particular, the insulating sleeve
shall not have punctured or rucked up.
which may affect safety or impair the further use
of the plug, in particular, the insulating sleeve
shall not have punctured or rucked up.
P
J2.2.6.7
Equipment with integral pins intended to be
supported by the contacts of a socket-outlet
supported by the contacts of a socket-outlet
Torque:
0.06 Nm (Normal position);
0.08 Nm (Reverse position).
0.08 Nm (Reverse position).
P
Click on the first or last page to see other ON STAGE III IIIP (serv.man2) service manuals if exist.