AS/NZS 3112 (Partial) 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
 
 
After the test the specimen shall be allowed to 
return to room temperature and then examined, 
No cracks of the insulating material shall be 
visible with normal, or corrected to normal, vision 
without additional magnification. 
NOTE: The cooling period of 14 h includes the 
time necessary to cool down the apparatus. 
 
 
 
(e) Abrasion test (2.13.13.6) 
 
 
An insulated pin of an insulated pin plug shall be 
subjected to the following test by means of an 
apparatus as shown in Figure 2.7. 
 
 
The test apparatus comprises a horizontally 
disposed beam, which shall be pivoted about its 
centre point. A short length of steel wire, 1 mm in 
diameter and bent into a U-shape, the base of the 
U being straight, shall be rigidly attached, at both 
ends, to one end of the beam, so that the straight 
part projects below the beam and shall be parallel 
to the axis of the beam pivot. 
 
 
The plug shall be held in a suitable clamp in such 
a position that the straight part of the steel wire 
rests on the major axis face of the plug pin, at 
right angles to it. The pin shall slope downwards 
at an angle of 10º to the horizontal. 
 
 
The beam shall be loaded so that the wire exerts 
a force of 4 N on the pin. 
 
 
The plug shall be moved backwards and forwards 
in horizontal direction in the plane of the axis of 
the beam, so that the wire rubs along the pin. The 
length of the pin thus abraded shall be 
approximately 9 mm, of which approximately 7 
mm shall be over the insulation. 
 
 
The number of movement s shall be 20 000 (10 
000 in each direction) and the rate of operation 
shall be 30 movements per min. 
 
 
After the test, the pins shall show no damage 
which may affect safety or impair the further use 
of the plug, in particular, the insulating sleeve 
shall not have punctured or rucked up. 
 
J2.2.6.7 
Equipment with integral pins intended to be 
supported by the contacts of a socket-outlet 
Torque:  
0.06 Nm (Normal position); 
0.08 Nm (Reverse position). 
 