Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online
<12014238 001 >
Page 67 of 77
AS/NZS 3112 (Partial)
Clause
Requirement − Test
Result – Remark
Verdict
The Australian plug was tested according to Annex J of AS/NZS 3112.
Appendix J
P
J1
Scope
P
This Appendix applies to only the plug portion of
equipment with integral pins and shall be read in
conjunction with section 2 contained in the body of
this standard. Where the term ‘plug’ is used in
section 2 it shall be taken to mean the plug portion
of equipment with integral pins.
equipment with integral pins and shall be read in
conjunction with section 2 contained in the body of
this standard. Where the term ‘plug’ is used in
section 2 it shall be taken to mean the plug portion
of equipment with integral pins.
Plug portion with integrated
pins
pins
P
J2
Requirements for plug portion
P
J2.1
definition
P
J2.2
requirments
See below.
P
J2.2.1
Plug pins of plug portions
P
Material for pins
Copper alloy containing 62%
copper.
copper.
P
Assembly of pins
P
Form of pin
P
Insulation of plug pin
P
J2.2.2
Ratings and dimensions for low voltage plug
portions
portions
Comply with 10A 250V two-pin
plug.
plug.
P
General
P
Compliance with dimensional requirements of
Figure 2.1
Figure 2.1
See attached dimension table.
P
J2.2.3
N/A
J2.2.4
Arrangement of earthing connections for plug
portions
portions
N/A
J2.2.5
Configuration of plug portions
P
J2.2.6.1
General
Noted
J2.2.6.2
High voltage test (3112.2.13.3)
P
The plug shall withstand without failure an a. c.
voltage of the value indicated in Table 2.3, applied
between the parts set our in Items (a) and (c) of
Clause 2.13.2 for 1 min in each case.
voltage of the value indicated in Table 2.3, applied
between the parts set our in Items (a) and (c) of
Clause 2.13.2 for 1 min in each case.
P
The plug shall further withstand, without failure, a
voltage of 3500 V a. c. applied between the parts
set out in Items (b) and (d) of Clause 2.13.2 for 1
min in each case.
voltage of 3500 V a. c. applied between the parts
set out in Items (b) and (d) of Clause 2.13.2 for 1
min in each case.
P