ON BEAT MICRO (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 81

Read JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate online

Issue Date: 
2012-10-23 
Page 31 of 41 
Report Reference # 
E204594-A37-CB-1 
 
 
 
 
 
IEC 60950-1:2005 
SubClause  Difference + Test 
Result - Remark 
Verdict 
 
 
This report issued under the responsibility of UL 
  
3.1.1
 
 
            Permissible combinations of internal 
wiring/external cable sizes for overcurrent and 
short circuit protection. 
           
 
             
           
N/A
 
3.1.1
 
 
            All interconnecting cables protected against 
overcurrent and short circuit. 
           
 
             
           
N/A
 
3.2
 
 
            Wiring methods permit connection of 
equipment to primary power supply in accordance 
with the NEC and CEC, Part 1. 
           
 
            Class III unit.  No direct 
connection to mains supply. 
           
N/A
 
3.2.1
 
 
            Permitted use for flexible cords and plugs. 
           
 
             
           
N/A
 
3.2.1
 
 
            Flexible cords provided with attachment 
plug rated 125% of equipment current rating. 
           
 
             
           
N/A
 
3.2.1
 
 
            Any Class II equipment provided with 15 or 
20 A standard supply outlets, Edison-base 
lampholders or single pole disconnect device 
provided with a polarized type attachment plug. 
           
 
             
           
N/A
 
3.2.1.2
 
 
            Equipment intended for connection to DC 
mains supply power systems complies with special 
wiring requirements (e.g., no permanent 
connection to supply by flexible cord). 
           
 
             
           
N/A
 
3.2.1.2
 
 
            Equipment with one pole of the DC mains 
supply connected to both the equipment mains 
input terminal and the main protective earthing 
terminal provided with special instructions and 
construction provisions for earthing. 
           
 
             
           
N/A
 
3.2.1.2
 
 
            Equipment with means for connecting 
supply to earthing electrode conductor has no 
switches or protective devices between supply 
 
             
           
N/A
 
Page of 99
Display