Issue Date:
2012-10-23
Page 28 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
conductor.
1.7.1
Equipment voltage rating not higher than
rating of the plug except under special conditions.
N/A
1.7.6
Special fuse replacement marking for
operator accessible fuses.
N/A
1.7.7
Identification of terminal connection of the
equipment earthing conductor.
N/A
1.7.7
Connectors and field wiring terminals for
external Class 2 or Class 3 circuits provided with
marking indicating minimum Class of wiring to be
used.
N/A
1.7.7
Marking located adjacent to terminals and
visible during wiring.
N/A
2.1.1.1
Bare TNV conductive parts in the interior of
equipment normally protected against contact by a
cover intended for occasional removal are exempt
provided instructions include directions for
disconnection of TNV prior to removal of the cover.
N/A
2.3.1.b
Other telecommunication signaling systems
(e.g., message waiting) than described in 2.3.1(b)
are subject to M.4.
N/A
2.3.1.b
For TNV-2 and TNV-3 circuits with other
than ringing signals and with voltages exceeding
42.4 Vp or 60 V d.c., the maximum current limit
through a 2000 Ohm or greater resistor with loads
disconnected is 7.1 mA peak or 30 mA d.c. under
normal conditions.
N/A