Read JBL ON BEAT MICRO (serv.man3) EMC - CB Certificate online
Issue Date:
2012-10-23
Page 34 of 41
Report Reference #
E204594-A37-CB-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
This report issued under the responsibility of UL
than those specified in 3.3 if wiring is reliably
separated.
separated.
3.3.1
Terminals for the connection of neutral
conductor identified by a distinctive white marking
or other equally effective means.
N/A
3.3.3
Wire binding screw terminal permitted for
connection of No. 10 AWG (5.3 mm²) or smaller
conductor if provided with upturned lugs, cupped
washer or equivalent retention.
N/A
3.3.4
Terminals accept wire sizes (gauge) used
in the U.S. and Canada.
N/A
3.3.4
Terminals accept current-carrying
conductors rated 125% of the equipment current
rating.
N/A
3.3.5
First column of Table 3E requirement:
“Smaller of the RATED CURRENT of the
equipment or the PROTECTIVE CURRENT
RATING of the circuit under consideration.”
N/A
3.3.6
Field wiring terminals marked to indicate
the material(s) of the conductor appropriate for the
terminals used.
N/A
3.3.6
Connection of an aluminum conductor not
permitted to terminal for equipment earthing
conductor.
N/A
3.3.6
Field wiring connections made through the
use of suitable pressure connectors (including set
screw type), solder lugs or splices to flexible leads.
N/A