Read Harman Kardon SB 16 (serv.man9) EMC - CB Certificate online
Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 10 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
CA
3
General requirements
P
3.2A
[Add the following clause]
A component power supply complying with
CAN/CSA-C22.2 No. 60950 is considered to
comply with this construction and fault conditions
of this Standard after taking into account any
relevant conditions of acceptability.
CAN/CSA-C22.2 No. 60950 is considered to
comply with this construction and fault conditions
of this Standard after taking into account any
relevant conditions of acceptability.
N
4.2
Normal operating conditions
Considered. P
4.2.1
[Add the following after the fifth paragraph]
For apparatus intended for use at nominal 120 V
ac, the apparatus shall comply with this Standard
at supply voltages between 108 and 125 V. For
apparatus intended for use at nominal 240 V ac,
the apparatus shall comply with this Standard at
supply voltages between 216 and 250 V.
ac, the apparatus shall comply with this Standard
at supply voltages between 108 and 125 V. For
apparatus intended for use at nominal 240 V ac,
the apparatus shall comply with this Standard at
supply voltages between 216 and 250 V.
Added. P
4.2.10
[Add the following after the second paragraph]
As an alternative, a supply apparatus for general
use complying with CAN/CSA-C22.2 No. 223 or
CAN/CSA-C22.2 No. 60950 shall be acceptable.
use complying with CAN/CSA-C22.2 No. 223 or
CAN/CSA-C22.2 No. 60950 shall be acceptable.
Added. P
5
Marking and instructions
[Add the following paragraph]
Adhesive nameplates on commercial products
shall comply with CSA C22.2 No. 0.15.
shall comply with CSA C22.2 No. 0.15.
Not applied for.
N
5.1
Identification and supply ratings
[Add the following item]
[Add the following item]
hA) date of manufacture: a date or code
identifying the period of manufacture shall be
marked on the apparatus;
identifying the period of manufacture shall be
marked on the apparatus;
Ditto. N
5.3A
[Add the following clause]
Where a loudspeaker grille, removable from the
outside, is relied on as part of the enclosure (see
Clause 9.2), the following marking or equivalent
shall be visible on the enclosure after removal of
the grille:
“Caution — To prevent electric shock hazard,
replace grille.”
Alternatively, the symbol in Clause 5.2 b) shall be
visible after removal of the grille, and the caution
wording above shall appear in the user
instructions, accompanied by the symbol.
Compliance is checked by inspection.
outside, is relied on as part of the enclosure (see
Clause 9.2), the following marking or equivalent
shall be visible on the enclosure after removal of
the grille:
“Caution — To prevent electric shock hazard,
replace grille.”
Alternatively, the symbol in Clause 5.2 b) shall be
visible after removal of the grille, and the caution
wording above shall appear in the user
instructions, accompanied by the symbol.
Compliance is checked by inspection.
Not loudspeaker equipment.