Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 14 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
14.6.3
[Add the following paragraph]
As an alternative, a TV-rated switch complying
with CSA C22.2 No. 1, Clause 9, shall be
acceptable.
with CSA C22.2 No. 1, Clause 9, shall be
acceptable.
Not applied for.
N
14.6.4
[Add the following paragraph]
As an alternative, a TV-rated switch complying
with CSA C22.2 No. 1, Clause 9, shall be
acceptable.
with CSA C22.2 No. 1, Clause 9, shall be
acceptable.
Ditto. N
14.6.5
[Add the following paragraph]
As an alternative, a TV-rated switch complying
with CSA C22.2 No. 1, Clause 9, shall be
acceptable.
with CSA C22.2 No. 1, Clause 9, shall be
acceptable.
Ditto. N
14.11
Optocouplers
[Add the following paragraph]
As an alternative, an optocoupler complying with
CSA C22.2 No. 1 shall be acceptable.
CSA C22.2 No. 1 shall be acceptable.
Ditto. N
14.12
Surge suppression varistors
[Add the following paragraph]
As an alternative, a varistor complying with CSA
C22.2 No. 1 shall be acceptable.
C22.2 No. 1 shall be acceptable.
Ditto. N
14.12A
Gas discharge tubes
[Add the following clause]
Gas discharge tubes complying with the following
tests may be connected to bridge basic or
reinforced insulation. Ten samples of gas
discharge tubes isolating the ac supply from
exposed parts shall be subjected to the varistor
pulse tests of Clause 14.12. Following the
pulses, the device shall be allowed to return to
room temperature. The dielectric breakdown
voltage of the gas tube shall not decrease by
more than 50%, and the gas discharge tube shall
comply with the dielectric strength test of Clause
10.3, with the test voltage reduced to twice the
mains voltage.
tests may be connected to bridge basic or
reinforced insulation. Ten samples of gas
discharge tubes isolating the ac supply from
exposed parts shall be subjected to the varistor
pulse tests of Clause 14.12. Following the
pulses, the device shall be allowed to return to
room temperature. The dielectric breakdown
voltage of the gas tube shall not decrease by
more than 50%, and the gas discharge tube shall
comply with the dielectric strength test of Clause
10.3, with the test voltage reduced to twice the
mains voltage.
Ditto. N