Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 5 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
16.2
In Table 18, in the second and third rows of the
first column replace ‘6’ with ‘7.5’.
first column replace ‘6’ with ‘7.5’.
N
16.3
In item (b), add the following:
A flexible cord complying with AS/NZS 3191
need not undergo this test.
A flexible cord complying with AS/NZS 3191
need not undergo this test.
Not applied for.
N
20
Add the following after NOTE 2:
For alternative test refer to Clause 20.201.
For alternative test refer to Clause 20.201.
Ditto. N
20.1.4
In Table 21, in the third and fourth columns
change both ‘HB75’ and ‘No requirement’ to ‘V-
1’.
change both ‘HB75’ and ‘No requirement’ to ‘V-
1’.
Ditto. N
20.2.3
After this Clause, add the following variation:
20.201 Resistance to fire—Alternative tests
20.201.1 General
Parts of non-metallic material shall be resistant to ignition and the spread of fire.
This requirement does not apply to decorative trims, knobs and other parts
unlikely to be ignited or to propagate flames originating from inside the
apparatus, or the following:
20.201.1 General
Parts of non-metallic material shall be resistant to ignition and the spread of fire.
This requirement does not apply to decorative trims, knobs and other parts
unlikely to be ignited or to propagate flames originating from inside the
apparatus, or the following:
a) Components that are contained in an enclosure having a flammability category
of V-0 according to AS/NZS 60695.11.10 and having openings only for the
connecting wires filling the openings completely, and for ventilation not exceeding
1 mm in width regardless of length.
of V-0 according to AS/NZS 60695.11.10 and having openings only for the
connecting wires filling the openings completely, and for ventilation not exceeding
1 mm in width regardless of length.
b) The following parts which would contribute negligible fuel to a fire:
-small mechanical parts, the mass of which does not exceed 4 g, such as
mounting parts, gears, cams, belts and bearings;
mounting parts, gears, cams, belts and bearings;
-small electrical components, such as capacitors with a volume not exceeding 1
750 mm3, integrated circuits, transistors and optocoupler packages, if these
components are mounted on material of flammability category V-1 or better
according to AS/NZS 60695.11.10.
NOTE – In considering how to minimize propagation of fire and what ‘small parts’
are, account should be taken of the cumulative effect of small parts adjacent to
each other for the possible effect of propagating fire from one part to another.
Compliance shall be checked by the tests of 20.201.2.1, 20.201.2.2. and
20.201.2.3
For the base material of printed boards, compliance shall be checked by the test
of 20.201.2.4.
The tests shall be carried out on parts of non-metallic material which have been
removed from the apparatus.
When the glow-wire test is carried out, they are placed in the same orientation as
they would be in normal use.
750 mm3, integrated circuits, transistors and optocoupler packages, if these
components are mounted on material of flammability category V-1 or better
according to AS/NZS 60695.11.10.
NOTE – In considering how to minimize propagation of fire and what ‘small parts’
are, account should be taken of the cumulative effect of small parts adjacent to
each other for the possible effect of propagating fire from one part to another.
Compliance shall be checked by the tests of 20.201.2.1, 20.201.2.2. and
20.201.2.3
For the base material of printed boards, compliance shall be checked by the test
of 20.201.2.4.
The tests shall be carried out on parts of non-metallic material which have been
removed from the apparatus.
When the glow-wire test is carried out, they are placed in the same orientation as
they would be in normal use.
N