Read Harman Kardon SB 16 (serv.man9) EMC - CB Certificate online
Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 12 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
10
Insulation requirements
See below.
P
10.2A
Enclosure type designation and use
[Add the following clause]
If equipment is installed in environments where
the enclosure is required to prevent ingress of
water or dust, the enclosure shall be classified as
a type recognized by the
the enclosure is required to prevent ingress of
water or dust, the enclosure shall be classified as
a type recognized by the
Canadian Electrical
Code, Part I, and shall comply with the
requirements of CAN/CSA-C22.2 No. 94.
requirements of CAN/CSA-C22.2 No. 94.
Not applied for.
N
11.2 Heating
[Add the following paragraph]
Flammable gases shall not be emitted from a
component for more than 10 s.
component for more than 10 s.
Considered. P
12.3A
Television impacts
[Add the following clause]
Not applied for.
N
12.3A.1
For television sets and similar apparatus using a
cathode ray tube larger than 160 mm diagonally,
the top, sides, front, and rear of the enclosure,
including the safety screen where provided, shall
be capable of withstanding a single impact of 7 J
in accordance with Clause 12.3A.2 without
developing any opening larger than 130 mm in
the enclosure of the cathode ray tube, unless the
minor dimension of 2 any opening is not more
than 7 mm.
When applied to a safety screen, the impact shall
not result in damage to its mounting to the extent
that it is mechanically unsuitable for reuse, nor
shall tempered glass, if used, be cracked.
cathode ray tube larger than 160 mm diagonally,
the top, sides, front, and rear of the enclosure,
including the safety screen where provided, shall
be capable of withstanding a single impact of 7 J
in accordance with Clause 12.3A.2 without
developing any opening larger than 130 mm in
the enclosure of the cathode ray tube, unless the
minor dimension of 2 any opening is not more
than 7 mm.
When applied to a safety screen, the impact shall
not result in damage to its mounting to the extent
that it is mechanically unsuitable for reuse, nor
shall tempered glass, if used, be cracked.
When applied to the face of a directly viewed
cathode ray tube, the impact shall not cause any
opening in the face of the tube.
Scaling and cracking of the glass shall be
permissible. A cathode ray tube that has been
shown to comply with CAN/CSA-C22.2 No. 228
or CAN/CSA-E61965 shall be considered
acceptable with no further tests.
cathode ray tube, the impact shall not cause any
opening in the face of the tube.
Scaling and cracking of the glass shall be
permissible. A cathode ray tube that has been
shown to comply with CAN/CSA-C22.2 No. 228
or CAN/CSA-E61965 shall be considered
acceptable with no further tests.
Ditto. N
12.3A.2
The impact specified in Clause 12.3A.1 shall be
caused by allowing a solid, smooth, steel sphere
51 mm in diameter and weighing approximately
0.5 kg to strike the enclosure with the specified
impact in a direction perpendicular to the
enclosure surface. If deemed necessary, the
enclosure shall be tested with the proper cathode
ray tube mounted.
caused by allowing a solid, smooth, steel sphere
51 mm in diameter and weighing approximately
0.5 kg to strike the enclosure with the specified
impact in a direction perpendicular to the
enclosure surface. If deemed necessary, the
enclosure shall be tested with the proper cathode
ray tube mounted.
Ditto. N