Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 6 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
These tests are not carried out on internal wiring.
20.201.2 Tests
20.201.2 Tests
20.201.2.1 Testing of non-metallic parts
Part of non-metallic material shall be subject to the glow-wire test of AS/NZS
60695.2.11 which shall be carried out at 550°C.
Parts for which the glow-wire test cannot be carried out, such as those made of
soft or foamy material, shall meet the requirements specified in ISO 9772 for
category FH-3 material. The glow-wire test shall not be carried out on parts of
material classified at least FH-3 according to ISO 9772 provided that the sample
tested was not thicker than the relevant part.
Part of non-metallic material shall be subject to the glow-wire test of AS/NZS
60695.2.11 which shall be carried out at 550°C.
Parts for which the glow-wire test cannot be carried out, such as those made of
soft or foamy material, shall meet the requirements specified in ISO 9772 for
category FH-3 material. The glow-wire test shall not be carried out on parts of
material classified at least FH-3 according to ISO 9772 provided that the sample
tested was not thicker than the relevant part.
N
20.201.2.2 Testing of insulated parts
Part of insulating material supporting potential ignition sources shall be subject to
the glow-wire test of AS/NZS 64695.2.11 which shall be carried out at 750°C.
The test shall be also carried out on other parts of insulating material which are
within a distance of 3 mm of the connection
NOTE – Contacts in components such as switch contacts are considered to be
connections.
Part of insulating material supporting potential ignition sources shall be subject to
the glow-wire test of AS/NZS 64695.2.11 which shall be carried out at 750°C.
The test shall be also carried out on other parts of insulating material which are
within a distance of 3 mm of the connection
NOTE – Contacts in components such as switch contacts are considered to be
connections.
N
For parts which withstand the glow-wire test but produce a flame, other parts
above the connection within the envelope of a vertical cylinder having a diameter
of 20 mm and a height of 50 mm shall be subjected to the needle-flame test.
However, parts shielded by a barrier which meets the needle-flame test need not
be tested.
The needle-flame test shall be made in accordance with AS/NZS 4695.2.2 with
the following modifications:
above the connection within the envelope of a vertical cylinder having a diameter
of 20 mm and a height of 50 mm shall be subjected to the needle-flame test.
However, parts shielded by a barrier which meets the needle-flame test need not
be tested.
The needle-flame test shall be made in accordance with AS/NZS 4695.2.2 with
the following modifications:
N