Page 15 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9 
Clearance measured between 
different polarity of mains at: 
−  Power cord wires: 10,9mm 
(measured on power switch 
board) 
(Limit: 
≥ 2,0mm) 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
 P 
13.4 
Creepage distances      
 
Creepage distances greater than table 11 minima  Creepage distance measured 
between different polarity of 
mains at: 
−  Power cord wires: 10,9mm 
(measured on power switch 
board) 
(Limit: 
≥ 2,3mm) 
13.5 
Printed boards      
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 P 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 N 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 N 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 N 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
 N 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
 N 