Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
Clearance measured between
different polarity of mains at:
different polarity of mains at:
− Power cord wires: 10,9mm
(measured on power switch
board)
board)
(Limit:
≥ 2,0mm)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
P
13.4
Creepage distances
Creepage distances greater than table 11 minima Creepage distance measured
between different polarity of
mains at:
mains at:
− Power cord wires: 10,9mm
(measured on power switch
board)
board)
(Limit:
≥ 2,3mm)
P
13.5
Printed boards
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
P
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
N
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N