Page 10 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 
 
Basic or supplementary insulation, three layers 
any two of which meet 10.3 
 
 
Reinforced insulation, two layers each of which 
meet 10.3 
2 layers of insulating tape 
enclosed primary winding of 
stand-by transformer, each 
layer with thickness of 0,04mm 
and fulfils 4240Vpeak 
(reinforced insulation) 
 
Reinforced insulation, three layers any two which 
meet 10.3 
 N 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
1.  Thickness of double 
insulated primary lead 
wires of mains transformer 
and power cord wires: 
1,2mm 
2.  Thickness of double 
insulated primary lead 
wires of stand-by 
transformer: 0,8mm 
3.  Thickness of double 
insulated primary wires of 
mains fuse-link (FUSE): 
0,74mm 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
Basic insulated secondary wire 
cannot touch live parts       
8.10 
Double insulation between conductors connected 
to the mains and accessible parts 
Double insulated primary wires 
fulfil 4240V peak 