Page 14 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N
Class I protective earthing maintained
N
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
N
11.2.5
Temperature rise of windings
(see appended table)
P
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
N
12 MECHANICAL
STRENGTH
12.1.1
Bump test where mass >7 kg
Measured mass: 12,7kg > 7kg;
no damage
no damage
P
12.1.2
Vibration test
No damage
P
12.1.3
Impact hammer test
No damage
P
Steel ball test
No damage
P
12.1.4
Drop test for portable apparatus where mass
≤ 7
kg
Not portable apparatus
N
12.1.5
Thermoplastic enclosures stress relief test
After 7h with used temperature
70
70
°C, hazardous live parts did
not become accessible
P
12.2
Fixing of knobs, push buttons, keys and levers
No such device
N
12.3
Remote controls with hazardous live parts
No such device
N
12.4
Drawers (pull test 50 N, 10 s)
N
12.5
Antenna coaxial sockets providing isolation
No such device
N
12.6
Telescoping or rod antennas construction
No such device
N
12.6.1
Telescoping or rod antennas securement
N
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
Pollution degree: 2
P
Creepage distances in accordance with 13.4
Pollution degree: 2 and
material group IIIb
material group IIIb
P
13.2
Determination of operating voltage
Operating voltage: 230V
P
13.3
Clearances