HK 970 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 23

Read Harman Kardon HK 970 (serv.man13) EMC - CB Certificate online

 
 
Page 19 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Insulation between: 
1. Primary 
winding 
to 
accessible iron core of 
mains and stand-by 
transformers fulfil 4240V 
peak (reinforced 
insulation) 
2. Primary 
winding 
to 
secondary winding of 
mains and stand-by 
transformers fulfil 4240V 
peak (reinforced 
insulation) 
 
Coil formers and partition walls  
≥ 0,4 mm 
 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 
14.4 
High voltage components 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
No such component 
 
Component meets category V-1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 N 
14.5 
Protective devices 
 
Protective devices used within their ratings 
 
Page of 98
Display