Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
8.17 
Insulated winding wire without additional 
interleaved insulation 
No such wire 
8.18 
Endurance test as required by 8.17 
 
8.19 
Disconnection from the mains 
8.19.1 
Disconnect device 
Mains plug used and complied 
with clause 5.4.2(a) 
 
All-pole switch or circuit breaker with 
≥3mm 
contact separation 
No such device 
8.19.2 
Mains switch ON indication 
No such device 
8.20 
Switch not fitted in the mains cord 
 
8.21 
Bridging components comply with clause 14 
No such component 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No such circuit 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ................................ :
Measured maximum: 
U1: 314,0mV peak < 35Vpeak 
U2: 22,8mV peak < 0,35Vpeak 
 
Discharge not exceeding 45 µC 
Measured discharge: 47,3nC 
 
Energy of discharge not exceeding 350 mJ 
Open circuit voltage < 15kV 
9.1.1.2 
Test with test finger and test probe 
No hazardous live parts 
became accessible 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 N 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin 
Top ventilation holes < 4mm 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
 P 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 P 
9.1.5 
Pre-set controls tested with 2,5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No such device 