Read Harman Kardon HK 970 (serv.man13) EMC - CB Certificate online
Page 11 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
1. Primary lead wires of
mains and stand-by
transformer; mains fuse-
link (FUSE) and power
cord wires were soldered
to PCB through eye-lets
terminals and fixed by
glue and cable-ties
transformer; mains fuse-
link (FUSE) and power
cord wires were soldered
to PCB through eye-lets
terminals and fixed by
glue and cable-ties
2. Primary lead wires of
mains fuse-link (FUSE)
were soldered to terminals
of fuse-holder by hook-in
method which enclosed by
heat-shrinkable tubing and
fixed by glue and cable-
ties
were soldered to terminals
of fuse-holder by hook-in
method which enclosed by
heat-shrinkable tubing and
fixed by glue and cable-
ties
3. Secondary lead wires of
stand-by transformer were
soldered to PCB through
eye-lets terminals and
fixed by glue
soldered to PCB through
eye-lets terminals and
fixed by glue
4. Secondary lead wires of
mains transformer and
other secondary wires
connected to PCB with
connector terminals and
fixed by cable-ties
other secondary wires
connected to PCB with
connector terminals and
fixed by cable-ties
P
Vibration test carried out ....................................... : Yes, no damage
P
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
N
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
N
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
N
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
Not this type of equipment
N
Click on the first or last page to see other HK 970 (serv.man13) service manuals if exist.