HK 970 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 15

Read Harman Kardon HK 970 (serv.man13) EMC - CB Certificate online

 
 
Page 11 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
8.11 
Detaching of wires      
 
No undue reduction of creepages or clearance 
distances if wires become detached 
1.  Primary lead wires of 
mains and stand-by 
transformer; mains fuse-
link (FUSE) and power 
cord wires were soldered 
to PCB through eye-lets 
terminals and fixed by 
glue and cable-ties 
2.  Primary lead wires of 
mains fuse-link (FUSE) 
were soldered to terminals 
of fuse-holder by hook-in 
method which enclosed by 
heat-shrinkable tubing and 
fixed by glue and cable-
ties 
3.  Secondary lead wires of 
stand-by transformer were 
soldered to PCB through 
eye-lets terminals and 
fixed by glue 
4.  Secondary lead wires of 
mains transformer and 
other secondary wires 
connected to PCB with 
connector terminals and 
fixed by cable-ties 
 
Vibration test carried out  ....................................... : Yes, no damage 
8.12 
Adequate cross-sectional area of internal wiring to 
mains socket-outlets 
 N 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
 
8.16 
Only special supply equipment can be used 
Not this type of equipment 
Page of 98
Display