Read Harman Kardon HK 970 (serv.man13) EMC - CB Certificate online
Page 7 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
1. Creepage
distance
and
clearance measured on
power switch board which
between:
power switch board which
between:
− Primary and secondary of
relay (RL901): 6,7mm
− Soldering pad of power cord
wire (AC1) and metal
enclosure (through screw
post): 6,65mm
enclosure (through screw
post): 6,65mm
− Soldering pad of mains
fuse-link (FUSE) and metal
enclosure (through screw
post): 6,25mm
enclosure (through screw
post): 6,25mm
− Track of L901 and metal
enclosure (through screw
post): 6,25mm
post): 6,25mm
− Track of R901 and metal
enclosure (through screw
post): 6,35mm
post): 6,35mm
− Track of primary lead wire of
mains transformer and metal
enclosure (through screw
post): 7,85mm
enclosure (through screw
post): 7,85mm
(Limits: (Cr.)
≥ 4,6mm;
(Cl.)
≥ 4,0mm)
2. Clearance
measured
between:
− Soldering terminal of
primary lead wire of mains
transformer (T1) on power
switch board and metal
enclosure: 8,55mm
transformer (T1) on power
switch board and metal
enclosure: 8,55mm
− Primary winding of mains
transformer and metal
enclosure: 19,3mm
enclosure: 19,3mm
(Limits:
≥ 4,0mm)
P