Page 7 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
1. Creepage 
distance 
and 
clearance measured on 
power switch board which 
between: 
−  Primary and secondary of 
relay (RL901): 6,7mm 
−  Soldering pad of power cord 
wire (AC1) and metal 
enclosure (through screw 
post): 6,65mm 
−  Soldering pad of mains 
fuse-link (FUSE) and metal 
enclosure (through screw 
post): 6,25mm 
−  Track of L901 and metal 
enclosure (through screw 
post): 6,25mm 
−  Track of R901 and metal 
enclosure (through screw 
post): 6,35mm 
−  Track of primary lead wire of 
mains transformer and metal 
enclosure (through screw 
post): 7,85mm 
(Limits: (Cr.) 
≥ 4,6mm;  
(Cl.) 
≥ 4,0mm) 
2. Clearance 
measured 
between: 
−  Soldering terminal of 
primary lead wire of mains 
transformer (T1) on power 
switch board and metal 
enclosure: 8,55mm 
−  Primary winding of mains 
transformer and metal 
enclosure: 19,3mm 
(Limits: 
≥ 4,0mm) 