IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Not used
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools are required
N
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No such material
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
Clause 8.6 was complied
P
8.5
Class I equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
Class II apparatus
N
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
N
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
Class II apparatus
P