Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
 
SE  Sweden 
 
Annex B       
Replace NOTE 1 by 
In the CENELEC countries listed in IEC 62151, 
special national conditions apply. 
Add the following: 
All subclauses given below are subclauses of IEC 
62151:2000 (ref. Corrigendum 1 and 2 to IEC 
62151). 
Subclause 4.1.1 (Corrigendum 2):  
Add after the first paragraph: 
NOTE - In Sweden, CLASS I equipment which is 
intended for connection to the building installation 
via a non-industrial plug or a non-industrial 
appliance coupler, or both and in addition is 
intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
ACCESSIBLE parts, have a marking stating that 
the equipment must be connected to an earthed 
mains socket -outlet. 
The marking text shall be as follows: 
"Apparaten skall anslutas till 
jordat uttag‖ 
Subclause 5.3.1 (Corrigendum 1): 
Add after the first test specifications paragraph: 
NOTE 1 In Finland, Norway and Sweden, there 
are additional requirements for the insulation. 
Renumber the existing note as note 2. 
For additional requirements for the insulation in 
Sweden in the NOTE 1 the following text is added 
between the first and second paragraph (this text 
is identical to the text in EN 60950-1:2001): 
If this insulation is solid, including insulation 
forming part of a component, it shall at least 
consist of either 
- two layers of thin sheet material, each of which 
shall pass the electric strength test below, or 
- one layer having a distance through insulation of 
at least 0,4 mm, which shall pass the electric 
strength test below. 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES and CREEPAGE DISTANCES do 
not exist, if the component passes the electric 
strength test in the accordance with the 
compliance clause below and in addition: 
- passes the test and inspection criteria of 13.6 
with an electric strength test of 10.3 using the test 
voltage of 1,5 kV multiplied by 1,6, and 
- is subject to routine testing for electric strength 
during manufacturing, using a test voltage of 1,5 
kV (for performance of the test see N.2.1). 
 
N/A 