Read Harman Kardon AVR 360 EMC - CB Certificate online
- Page 14 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
12 Mechanical
strength
12.1.1
Bump test where mass >7 kg ……………………...:
No damage in the sense of
this standard
this standard
P
12.1.2
Vibration test …………………………………………:
Assessed to be satisfactory
constructed.
constructed.
N/A
12.1.3
Impact hammer test ………………………………...:
No damage in the sense of
this standard
this standard
P
Steel ball test ………………………………………...:
No damage in the sense of
this standard
this standard
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg:
Not portable apparatus
N/A
12.1.5
Thermoplastic enclosures stress relief test …….:
Tested, 70ºC, 7h
P
12.2
Fixing of knobs, push buttons, keys and levers ..:
Normal use will not impair the
protection against electric
shock.
protection against electric
shock.
P
12.3
Remote controls with hazardous live parts ….:
No cable connected
remote control devices.
remote control devices.
N/A
12.4
Drawers (pull test 50 N, 10 s) …………………:
No drawers
N/A
12.5
Antenna coaxial sockets providing isolation …:
No antenna
N/A
12.6
Telescoping or rod antennas construction …….:
No telescoping or rod antennas
N/A
12.6.1
Telescoping or rod antennas securement …….....:
N/A
13
Clearances and creepage distances
13.1
Clearances in accordance with 13.3 ………………:
See 13.3
P
Creepage distances in accordance with 13.4 …….:
See 13.4
P
13.2
Determination of operating voltage …..……:
Conventional
linear transf. used.
Rated supply voltage (240V)
applied in determining the
operating voltage.
applied in determining the
operating voltage.
P
13.3 Clearances
2N for internal parts and 30N
for enclosures are considered
when determining clearances.
for enclosures are considered
when determining clearances.
P
13.3.1 General
…………………………:
Considered
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9 ………..:
with table 8 and, where applicable, table 9 ………..:
(see appended table 13)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10 ……………...:
comply with table 10 ……………...:
No hazardous secondary
voltages
voltages
N/A