Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin ……:
4 mm x 100 mm test pin ……:
No access for the test pin
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032 …………………:
(10 N); test probe D of IEC 61032 …………………:
Does not reach hazardous live
parts
parts
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032 ……:
straight wire (1 N); test probe D of IEC 61032 ……:
Does not reach hazardous live
parts
parts
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
……………….:
pin (10 N); test probe C of IEC 61032
……………….:
No preset controls
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after
2 s …:
withdrawal of the mains plug; voltage (V) after
2 s …:
See below
N/A
If C is not greater than 0,1 μF no test needed ……:
<
0,1 μF
P
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N) …...:
Test with test finger
result in no hazard
result in no hazard
P
b) Test hook of fig. 4 for 10 s (20 N) ……:
Test with test hook results in
no hazard.
no hazard.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N) :
Tested with 100N results in
no damage.
no damage.
P
9.2
No hazard after removing a cover by hand ……….:
No cover removable by hand
N/A
10 Insulation
requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ……………………………………………..:
surge test for basic and 4 MΩ min. for reinforced
insulation ……………………………………………..:
> 100 M
Ω after surge test
P
10.2
Humidity treatment 48 h or 120 h ………………….:
Performed for 120 h at temp.
40
40
°C and humidity 93%
P
10.3
Insulation resistance and dielectric strength between
mains terminals ……………………………………...:
mains terminals ……………………………………...:
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1) :
BASIC or SUPPLEMENTARY insulation (Class 1) :
Class II apparatus
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II) ……………..:
REINFORCED insulation (Class II) ……………..:
(see appended table 10.3)
P