Read Harman Kardon AVR 360 EMC - CB Certificate online
- Page 18 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.5.1.2
a) Thermal links separately approved …………..:
Thermal link in main transf.,
separately approved compo.
See appended table,
list of critical components
separately approved compo.
See appended table,
list of critical components
P
b) Thermal links tested as part of the submission ….:
N/A
14.5.1.3
Thermal devices re-settable by soldering …………:
No thermal device
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
……………………………………………….......:
60127
……………………………………………….......:
Fuses are approved
components according to
IEC 60127.
See appended table, list of
critical components.
components according to
IEC 60127.
See appended table, list of
critical components.
P
14.5.2.2
Correct marking of fuse-links adjacent to
holder ……:
holder ……:
The following marking applied;
Mains fuses;
F901: T6.3A L 250V
F902: T2.5A L 250V
F901: T6.3A L 250V
F902: T2.5A L 250V
Secondary fuse;
F110: T5A L 250V
F111: T5A L 250V
F110: T5A L 250V
F111: T5A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ………….:
No fuse holder so designed
that fuse-links can be
connected in parallel
that fuse-links can be
connected in parallel
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ……..:
replacing fuse-links without the use of a tool ……..:
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
……….:
……….:
No PTC’s thermistors.
N/A
PTC-S devices (15 W) category V-1 or better
………:
………:
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked …………......:
No such components
N/A
14.6 Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1 ……………...:
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1 ……………...:
Mains switch and relay are
certified components
according to IEC 61058-1.
See appended table,
list of critical components.
certified components
according to IEC 61058-1.
See appended table,
list of critical components.
P
Click on the first or last page to see other AVR 360 service manuals if exist.