AVR 360 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 13

Read Harman Kardon AVR 360 EMC - CB Certificate online

 
 
- Page 9 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
Constructional requirements with regard to the protection against electric shock 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare …………: 
Considered 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
………….: 
Operation “By hand” not 
possible 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material ………..: 
No hygroscopic materials 
used 
N/A 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand: 
No cover removable by hand 
N/A 
8.5 
Class I equipment …………………...: 
Class II equipment 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts ……………………………: 
 
N/A 
 
Resistors bridging basic insulation complying with 
14.1 a) ……………..: 
No such resistors 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a) ……………………….......:  
No such capacitors 
N/A 
 
Protective earthing terminal …………...: 
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment …………………...: 
Class II equipment 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts ………..: 
Double/Reinforced insulation 
complies with requirements 
specified in clause 10 and 13. 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3 ……..: 
The apparatus has isolating 
transformers complies with  
clause 14.3 
 
Basic insulation bridged by components complying 
with 14.3.4.3. ………………………...: 
No such components 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) …: 
No such capacitors. 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a) …….: 
No such capacitors. 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b) ………: 
No such capacitors 
N/A 
Page of 65