Read Harman Kardon AVR 360 EMC - CB Certificate online
- Page 9 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
8
Constructional requirements with regard to the protection against electric shock
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare …………:
untreated textile oxide films and beads etc.
considered to be bare …………:
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
………….:
device, fuse-links or handling drawers etc.
………….:
Operation “By hand” not
possible
possible
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material ………..:
hygroscopic material ………..:
No hygroscopic materials
used
used
N/A
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand:
from parts rendered accessible following the
removal of a cover which can be removed by hand:
No cover removable by hand
N/A
8.5
Class I equipment …………………...:
Class II equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts ……………………………:
earthed accessible parts ……………………………:
N/A
Resistors bridging basic insulation complying with
14.1 a) ……………..:
14.1 a) ……………..:
No such resistors
N/A
Capacitors bridging basic insulation complying with
14.2.1 a) ……………………….......:
14.2.1 a) ……………………….......:
No such capacitors
N/A
Protective earthing terminal …………...:
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment …………………...:
Class I equipment …………………...:
Class II equipment
P
Double or reinforced insulation between hazardous
live parts and accessible parts ………..:
live parts and accessible parts ………..:
Double/Reinforced insulation
complies with requirements
specified in clause 10 and 13.
complies with requirements
specified in clause 10 and 13.
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3 ……..:
complying with 14.1 a) or 14.3 ……..:
The apparatus has isolating
transformers complies with
clause 14.3
transformers complies with
clause 14.3
P
Basic insulation bridged by components complying
with 14.3.4.3. ………………………...:
with 14.3.4.3. ………………………...:
No such components
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a) …:
bridged by a capacitor complying with 14.2.1 a) …:
No such capacitors.
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a) …….:
capacitors in series complying with 14.2.1 a) …….:
No such capacitors.
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b) ………:
single capacitor complying with 14.2.1 b) ………:
No such capacitors
N/A